m+Medelevator.RU
← Поиск публикаций
International orthopaedics · 2023

The Saint-Joseph Acetabular score: a reproducible and accurate prediction of the outcome of open reduction and internal fixation of acetabular fractures.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Melhem Elias, Rizkallah Maroun, Abid Hichem, Moreau Pierre-Emmanuel, Upex Peter, Zaraa Mourad, Sadeqi Mansour, Jouffroy Pomme, Riouallon Guillaume

Аннотация

PURPOSE: Acetabular fractures are associated to an increased risk of subsequent hip osteoarthritis. The only available score for post-operative reduction assessment in acetabular fractures (Matta's score) is x-ray based. CT-scan was shown superior to X-rays in post-operative reduction assessment. We aim to describe a CT-scan-based post-operative reduction score in acetabular fractures and evaluate its accuracy and reproducibility.

METHODS: This is a retrospective study that includes 138 patients who underwent surgery for an acetabular fracture in our tertiary referral centre with a mean follow-up of 104.39±42.2 months. The post-operative CT-scan was reviewed and residual displacement (maximum gap and step) measured by three independent observers. The association between the occurrence of THA and the CT-scan measurements was evaluated. This led to a new prognostic score. The interobserver reliability and accuracy of this score were calculated.

RESULTS: Interobserver reproducibility for the residual maximal gap was 0.82 (95% CI [0.70-0.89]) and 0.61 (95% CI [0.52-0.70]) for the residual maximal step displacement measurements. We created a score from a logistic regression model, attributing 1 point for every 1 mm of residual maximal step displacement and 1 point for every 2 mm of residual maximal gap displacement. The interobserver reproducibility of this score was 0.78 (95% CI [0.71-0.84]), and its AUC was 0.79 (95% CI [0.69-0.88]).

CONCLUSION: This is the first CT-scan-based score for the assessment of residual displacement of a surgically treated acetabular fracture. It shows good interobserver reproducibility and accuracy in predicting the risk for secondary THA. It should be regularly used per-operatively (if per-operative 3D imaging is available) and post-operatively to predict the prognosis.

Предметные рубрики MeSH