MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2025.118245

Медицинская библиотека · Biosensors & bioelectronics · 2025

An allosteric DNAzyme-Based logic circuit intelligent electrochemiluminescence biosensor for the precise diagnosis of acute myocardial infarction.

Zhang Zhe, Dai Yao, Liu Jinhua, Zhou Yajie, Du Zhongdi, Zhu Runze, Xu Cheng, Sun Yudie, Zhang Kui

СтатьяПеревод в очереди

Аннотация

Acute myocardial infarction (AMI) is a life-threatening medical emergency that requires early diagnosis and prompt intervention. However, distinguishing AMI from other coronary artery diseases with similar clinical manifestations remains challenging. In this study, a novel electrochemiluminescence (ECL) biosensor was developed by integrating allosteric DNAzyme nanodevices with ECL resonance energy transfer (ECL-RET) probes to enable intelligent analysis of multiple miRNAs related to different coronary artery diseases. A series of DNA-based logic devices was constructed by integrating strand displacement reactions into a DNAzyme framework, including YES, AND, OR, and INHIBIT logic gates. The "INHIBIT-AND" logic circuits, which perform complex information processing, can effectively analyze multiple miRNAs and intelligently differentiate diseases similar to AMI. The final signal was detected using an ECL-RET probe synthesized by encapsulating Ru[(bpy)3]2+ reductive-oxidative (R-O) emitters and CdTe quantum dots (QD) oxidative-reductive (O-R) emitters into DNA-modified silica nanoparticles. The sensing platform can intelligently detect multiple miRNAs, with a detection limit of 62 aM (S/N = 3), ranging from 1 fM to 1 nM. This strategy was applied to patients' serum samples, providing a new idea for the autonomous and precise diagnosis of AMI.

Для цитирования: Zhang Zhe, Dai Yao, Liu Jinhua, Zhou Yajie, Du Zhongdi, Zhu Runze, Xu Cheng, Sun Yudie, Zhang Kui. An allosteric DNAzyme-Based logic circuit intelligent electrochemiluminescence biosensor for the precise diagnosis of acute myocardial infarction.. Biosensors & bioelectronics. 2025. DOI: 10.1016/j.bios.2025.118245.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.