MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivaf229

Медицинская библиотека · Interdisciplinary cardiovascular and thoracic surgery · 2025

Detection of Sleep-Disordered Breathing Using Carbon Nanotube Sensors Predicts Complications After Lung Surgery.

Nakashima Yasuhiro, Kobayashi Masashi, Asakawa Ayaka, Seto Katsutoshi, Ishibashi Hironori, Sonoda Shiro, Tateishi Tomoya, Tamaoka Meiyo, Miyazaki Yasunari, Okumoto Koshiro, Horiuchi Haruka, Nakajima Yoshikazu, Okubo Kenichi

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Sleep-disordered breathing significantly affects perioperative outcomes; however, it remains frequently undiagnosed. We aimed to evaluate the utility of a novel carbon nanotube sensor system for detecting postoperative breathing abnormalities and investigated its association with postoperative complications following thoracic surgery.

METHODS

In this prospective study, 86 patients who underwent anatomical lung resection without previously diagnosed obstructive sleep apnoea were monitored using carbon nanotube sensors from the immediate postoperative period through the first postoperative day. Abnormal breathing was defined as an ≥30% reduction in the peak sensor signal from baseline lasting more than 10 s, in accordance with standard hypopnea criteria used in polysomnography. Patient characteristics and complications were compared using Fisher's exact and Mann-Whitney U test. Multivariate logistic regression identified predictors of major complications.

RESULTS

Twenty-three patients (26.7%) exhibited abnormal breathing events (sleep-disordered breathing). This group had a higher proportion of males (87% vs 61.9%, P = .035), had more difficult intubation (42.1% vs 13.5%, P = .018), and more frequently received epidural anaesthesia in addition to general anaesthesia (65.2% vs 36.5%, P = .027). Multivariate analysis identified sleep-disordered breathing as an independent predictor of major complications (Clavien-Dindo grade ≥3; odds ratio 4.41, 95% CI 1.14-13.8, P = .011) and prolonged air leakage (odds ratio 15.6, 95% CI 2.39-102, P = .004).

CONCLUSIONS

The carbon nanotube sensor showed potential for detecting undiagnosed sleep-disordered breathing after thoracic surgery, independently associated with increased risk of major complications, particularly prolonged air leakage.

CLINICAL TRIAL REGISTRATION: UMIN-CTR (https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000035066). Trial number: UMIN000031533.

Для цитирования: Nakashima Yasuhiro, Kobayashi Masashi, Asakawa Ayaka, Seto Katsutoshi, Ishibashi Hironori, Sonoda Shiro, Tateishi Tomoya, Tamaoka Meiyo, Miyazaki Yasunari, Okumoto Koshiro, Horiuchi Haruka, Nakajima Yoshikazu, Okubo Kenichi. Detection of Sleep-Disordered Breathing Using Carbon Nanotube Sensors Predicts Complications After Lung Surgery.. Interdisciplinary cardiovascular and thoracic surgery. 2025. DOI: 10.1093/icvts/ivaf229.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.