Journal of analytical toxicology · 2025
Quantification of phosphatidylethanol 16:0/18:1 in blood using supercritical fluid chromatography-tandem mass spectrometry.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gomonit Munchelou M, Roman Markus, Skillman Britni N, Truver Michael T, Kronstrand Robert
Аннотация
Phosphatidylethanol (PEth) consists of phospholipids synthesized in erythrocyte cell membranes in the presence of ethanol and serves as a sensitive and specific indicator of alcohol consumption. Further research on PEth formation, degradation, and stability in postmortem (PM) samples would support its routine application in forensic toxicology. A supercritical fluid chromatography-tandem mass spectrometry (SFC-MS-MS) method was developed and validated to quantify PEth 16:0/18:1 in blood. PEth 16:0/18:1 was extracted from blood (0.25 g) using an 8:2 (v/v) heptane:2-propanol mixture. Method validation results met American National Standards Institute/Academy Standards Board 036 guidelines. Recovery was >48%, and matrix effects were <20%. The linear range was 10-2500 ng/g, and lower limit of quantification was 10 ng/g. Bias was ±17.7%, and precision was <17.1% for all quality control levels. Carryover, endogenous, and exogenous interferences were negligible. Extracts were stable beyond 72 hours. In a proof-of-concept study reanalyzing 35 PM case samples, PEth concentrations ranged between 32.6 to 2476 ng/g. Short-term stability studies showed that fortified bovine blood (200 ng/g) preserved with 0.4% sodium fluoride (NaF) stored at room temperature had a 6.6% concentration drop after 48 hours, while blood stored at 4°C decreased by 13.5% over 14 days. Additionally, human PEth-positive blood preserved with 0.4% NaF showed a 6.7% decrease in in vivo PEth concentrations compared to a 17.5% decrease in heparin-preserved blood after 14 days at 4°C, supporting the use of 0.4% NaF in reducing PEth degradation over time. An in vitro model was also developed to simulate early PM PEth changes. Results found that PEth formation occurred in an ethanol concentration-dependent manner with minimal degradation, and considerations should be taken when interpreting PEth concentrations in cases with long PM interval, and if the decedent had a high blood alcohol concentration level and was left at elevated temperatures. This is the first SFC-MS-MS method successfully developed and validated for the analysis of PEth in PM samples.