MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-024-05517-0

Медицинская библиотека · Analytical and bioanalytical chemistry · 2024

Bar adsorptive microextraction and liquid chromatography-diode array detection of synthetic cannabinoids in oral fluid.

Ahmad Samir M, Neng Nuno R, Queirós Cláudio R, Gaspar Helena, Nogueira José Manuel F

СтатьяПеревод в очереди

Аннотация

In recent years, synthetic cannabinoids (SCs) have become a major public health issue. For this reason, there is a need for innovative analytical methods that allow its monitoring in biological matrices. In this work, we propose a novel methodology to screen eight SCs (AM-694, cumyl-5F-PINACA, MAM-2201, 5F-UR-144, JWH-018, JWH-122, UR-144 and APINACA) in oral fluids. A bar adsorptive microextraction method followed by microliquid desorption combined with high-performance liquid chromatography with diode array detection (BAµE-µLD/HPLC-DAD) was developed to monitor the target SCs. The main factors affecting the BAµE technology were fully optimized for oral fluid analysis. Under optimized experimental conditions, the proposed methodology showed good linear dynamic ranges from 20.0 to 2000.0 µg L-1 (r2 > 0.99, relative residuals < 15%), limits of detection between 2.0 and 5.0 µg L-1 and suitable average recovery yields (87.9-100.5%) for the eight studied SCs. The intra- and interday accuracies (bias ≤ ± 14.7%) and precisions (RSD ≤ 14.9%) were also evaluated at three spiking levels. The validated methodology was then assayed to oral fluid samples collected from several volunteers. The proposed analytical approach showed remarkable performance and could be an effective alternative for routine monitoring of the target compounds in oral fluid.

Для цитирования: Ahmad Samir M, Neng Nuno R, Queirós Cláudio R, Gaspar Helena, Nogueira José Manuel F. Bar adsorptive microextraction and liquid chromatography-diode array detection of synthetic cannabinoids in oral fluid.. Analytical and bioanalytical chemistry. 2024. DOI: 10.1007/s00216-024-05517-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.