Using continuous intraoperative optical coherence tomography to classify swirling lens fragments during cataract surgery and to predict their impact on corneal endothelial cell damage.

Amir-Asgari Sahand, Hirnschall Nino, Findl Oliver

СтатьяПеревод в очереди

Аннотация

PURPOSE: To quantify and classify swirling lens fragments during cataract surgery and record their impact on the corneal endothelium using continuous intraoperative optical coherence tomography (OCT).

SETTING

Vienna Institute for Ocular Surgery, Hanusch Hospital, Vienna, Austria.

DESIGN

Prospective case series.

METHODS

Patients scheduled for cataract surgery without other ophthalmologic comorbidities were included. During surgery, continuous OCT recordings were performed to measure and score swirling lens fragments that came into contact with the corneal endothelium. Endothelial cell density (ECD) was measured preoperatively and 1 month postoperatively. In addition, the central corneal thickness and aqueous flare were measured preoperatively and 1 hour, 1 day, and 1 month postoperatively.

RESULTS

Continuous intraoperative OCT video recordings showed 104 swirling lens fragments in 40 eyes that came into contact with the corneal endothelium. A mean of 2.6 lens fragments (range 0 to 6) that came into contact were observed per eye. Small fragments and fragments touching the center of the endothelium had a significantly greater effect on postoperative ECD than other fragment parameters. The predictive power of the fragment score on ECD was found to be moderate (r(2) = 0.6).

CONCLUSIONS

Small swirling lens fragments touching the center of the corneal endothelium had a significant influence on ECD. With the newly developed fragment score, it was possible to predict the operative endothelial cell loss.

FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Amir-Asgari Sahand, Hirnschall Nino, Findl Oliver. Using continuous intraoperative optical coherence tomography to classify swirling lens fragments during cataract surgery and to predict their impact on corneal endothelial cell damage.. Journal of cataract and refractive surgery. 2016. DOI: 10.1016/j.jcrs.2016.04.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.