MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3265/nefrologia.pre2013.nov.12145

Медицинская библиотека · Nefrologia : publicacion oficial de la Sociedad Espanola Nefrologia · 2014

The effect of replacing aluminium hydroxide with calcium acetate/magnesium carbonate on serum phosphorus control in haemodialysis patients.

Arroyo David, Panizo Nayara, Abad Soraya, Vega Almudena, Pérez-de José Ana, López-Gómez Juan M

Оценочное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Calcium acetate/magnesium carbonate (MgCO3) is a phosphorus binder with advantages in terms of cost, safety and tolerance and it has a similar efficacy to other drugs. The objective of the study is to assess the effects of replacing aluminium hydroxide [Al(OH3)] with MgCO3 on phosphorus and calcium metabolism in a cohort of haemodialysis patients.

MATERIALS AND

METHODS

We included 21 patients with phosphorus <5mg/dl, with Al(OH3) as the only binder. The conversion to MgCO3 was carried out without changing the number of pills. We recorded clinical-demographic characteristics, treatment for secondary hyperparathyroidism and laboratory parameters before conversion and every month for four months.

RESULTS

Phosphataemia decreased from 4.52 ± 0.99 to 4.02 ± 1.07 mg/dl (p=.027), and there was a decrease in the calcium-phosphorus product from 40.20 ± 10.44 to 35.16 ± 11.06 mg2/dl2 (p=.037). We did not observe significant changes in levels of calcium, parathyroid hormone or 25-OH-vitamin D3. The daily number of pills prescribed was reduced from 3.33 ± 2.29 to 2.15 ± 2.21 (p=.020). Concomitant treatments were not altered. We observed an initial significant increase in magnesaemia from 2.21 ± 0.24 to 2.43 ± 0.39 mg/dl (p=.001), which subsequently remained stable. We found a decrease in serum aluminium from 14.91 ± 8.55 to 8.47 ± 3.98 µg/l (p=.004), with levels within the recommended range in all patients.

CONCLUSIONS

MgCO3 allowed good control of serum phosphorus in haemodialysis patients who were previously well controlled with Al(OH)3, using fewer daily pills. There was a slight increase in serum magnesium, without short-term clinical significance. We do not know the effects of this increase in the longer term.

Для цитирования: Arroyo David, Panizo Nayara, Abad Soraya, Vega Almudena, Pérez-de José Ana, López-Gómez Juan M. The effect of replacing aluminium hydroxide with calcium acetate/magnesium carbonate on serum phosphorus control in haemodialysis patients.. Nefrologia : publicacion oficial de la Sociedad Espanola Nefrologia. 2014. DOI: 10.3265/nefrologia.pre2013.nov.12145.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.