MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2018.02.005

Медицинская библиотека · European journal of radiology · 2018

Evaluation of median nerve by shear wave elastography and diffusion tensor imaging in carpal tunnel syndrome.

Cingoz Mehmet, Kandemirli Sedat Giray, Alis Deniz Can, Samanci Cesur, Kandemirli Guzin Cakir, Adatepe Nurten Uzun

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of the current study is to investigate the diagnostic role of shear-wave elastography and diffusion tensor imaging in patients with carpal tunnel syndrome.

MATERIAL AND

METHODS

The study included a total of 77 wrists; 18 normal, 35 wrists with mild, 9 wrists with moderate and 15 wrists with severe carpal tunnel syndrome. Elastography of the median nerve was performed by defining the boundaries of a segment of the nerve at sagittal plane at the level of proximal carpal row. Additionally, the cross-sectional area of the median nerve was evaluated. Fractional anisotropy and apparent diffusion coefficient measurements were carried out by placing region-of-interest at three levels: at pisiform bone (carpal tunnel inlet), mid carpal tunnel, and hook of hamate (carpal tunnel outlet).

RESULTS

Patients with carpal tunnel syndrome had higher elasticity values of median nerve (53.0 kPa; IQR 40.8-77.0 kPa) compared to control subjects. (36.8 kPa; IQR 31.0-39.9 kPa) Patients with moderate-severe carpal tunnel syndrome had higher elasticity values (82 kPa; IQR 64.0-95.5 kPa) compared to patients with mild carpal tunnel syndrome. (44 kPa; IQR 32.5-59.5 kPa) Patients with carpal tunnel syndrome had lower fractional anisotropy at mid-carpal level (0.382; IQR 0.330-0.495) compared to the control group. (0.494; IQR 0.434-0.537) Patients with moderate-severe carpal tunnel syndrome had lower fractional anisotropy values (0.366; IQR 0.331-0.407) and higher apparent diffusion coefficient values (1.509 mm2/s; IQR 1.374-1.733 mm2/s) compared to patients with mild carpal tunnel syndrome. (0,423; IQR 0.324-0.526 and 1.293 mm2/s; IQR 0.967-1.514 mm2/s)

CONCLUSION

Shear-wave elastography and diffusion tensor imaging are helpful imaging modalities in diagnosing carpal tunnel syndrome and assessing its severity.

Для цитирования: Cingoz Mehmet, Kandemirli Sedat Giray, Alis Deniz Can, Samanci Cesur, Kandemirli Guzin Cakir, Adatepe Nurten Uzun. Evaluation of median nerve by shear wave elastography and diffusion tensor imaging in carpal tunnel syndrome.. European journal of radiology. 2018. DOI: 10.1016/j.ejrad.2018.02.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.