MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2013/637513

Медицинская библиотека · Clinical & developmental immunology · 2013

Interleukin-15 (IL-15) and anti-C1q antibodies as serum biomarkers for ectopic pregnancy and missed abortion.

Daponte Alexandros, Deligeoroglou Efthimios, Pournaras Spyros, Hadjichristodoulou Christos, Garas Antonios, Anastasiadou Foteini, Messinis Ioannis E

СтатьяПеревод в очереди

Аннотация

Given the present lack of clinically useful tests for the accurate diagnosis of ectopic pregnancy (EP), there is a need to select out those immunological factors measured in the maternal serum, as potential biomarkers. Our assumption was that C1q/anti-C1q antibody complexes and serum levels of interleukin-15 (IL-15) may play a role in differentiating abortions (MAs) and EPs and normal pregnancies. We assessed whether their measurement could set the diagnosis in a case control study at 6-8 weeks consisting of 60 women with failed early pregnancy (30 EPs, 30 MAs) and 33 women with intrauterine pregnancies. Normal pregnancies contain anti-C1q antibodies more frequently compared to women with failed pregnancies, the lowest levels being found in EPs, but this lacked statistical significance and anti-C1q could not serve as a marker. However EP pregnancies had elevated IL-15 levels that could statistically significantly differentiate them from MAs and IUPs. Furthermore, when assessing IL-15 for the clinically important differentiation between IUP and EP, we found at a cut-off of 16 pg/mL a negative predictive value of 99 with a sensitivity for diagnosing an EP of 92%. According to these results, serum IL-15 is a promising marker differentiating an MA from an EP.

Для цитирования: Daponte Alexandros, Deligeoroglou Efthimios, Pournaras Spyros, Hadjichristodoulou Christos, Garas Antonios, Anastasiadou Foteini, Messinis Ioannis E. Interleukin-15 (IL-15) and anti-C1q antibodies as serum biomarkers for ectopic pregnancy and missed abortion.. Clinical & developmental immunology. 2013. DOI: 10.1155/2013/637513.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.