DOI 10.1016/j.hrthm.2026.04.032
Amiodarone's impact on substrate mapping for scar-related ventricular tachycardia: Insights from personalized heart digital twins.
Аннотация
BACKGROUND
Substrate mapping and ablation for scar-related ventricular tachycardia (VT) are often performed with concomitant amiodarone (AMD), which can modify VT inducibility and alter electrogram (EGM) signatures of arrhythmogenic substrate.
OBJECTIVE
This study aimed to evaluate how AMD influences VT inducibility and bipolar EGM markers using heart digital twins.
METHODS
The effects of AMD at 2 therapeutic concentrations were characterized using heart digital twins incorporating patient-specific ischemic substrate distributions. VT inducibility was tested from multiple sites, and the reentrant circuits were characterized. Identified features of virtual electroanatomic maps included low-voltage, prolonged-duration, high-fractionation EGMs and isochronal crowding (IC) zones. Composite multiple-wavefront pacing maps were used to reduce electroanatomic map dependence on wavefront direction.
RESULTS
AMD did not significantly change overall VT inducibility, although a nonsignificant trend toward fewer inducible sites emerged at higher doses. At the VT circuit level, several baseline circuits disappeared, new drug-associated pathways emerged, and persistent morphologies tended to exhibit longer cycle lengths. AMD broadened regions classified as abnormal by voltage, duration, and fractionation, expanding the apparent substrate and reducing mapping specificity. With a single pacing site, IC zones were within 9 mm of the critical isthmus, more targeted than abnormal signal features, and not appreciably expanded by AMD. Combining multiple pacing orientations markedly improved colocalization without loss of specificity.
CONCLUSION
Concomitant AMD alters VT morphology and expands abnormal regions identified during substrate mapping, potentially obscuring critical ablation targets. Functional mapping strategies emphasizing IC and incorporating multiple-wavefront directions may improve long-term procedural success of scar-related VT ablation, particularly when AMD cannot be withdrawn.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.