MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.108432

Медицинская библиотека · Cureus · 2026

A Rare Case of Methicillin-Susceptible Staphylococcus aureus Catheter-Related Bloodstream Infection Complicated by Acute Bacterial Meningitis and Refractory Septic Shock in Morocco: A Case Report.

Benoumrhar Youssef, Khlifi Tagzouti Nada, El Kamouni Youssef, Zouhair Said, Arsalane Lamiae

Клинический случайСтатьяПеревод в очереди

Аннотация

Catheter-related bloodstream infections (CRBSIs) remain a serious complication in patients with hematologic malignancies, regardless of the causative microorganism, although Staphylococcus aureus remains an important pathogen because of its potential for rapid progression and metastatic complications. This report details the case of a 58-year-old man receiving immunochemotherapy for diffuse large B-cell lymphoma who developed fulminant sepsis 72 hours following the implantation of a totally implantable venous access port. The patient presented with high-grade fever, acute confusion, and local signs of port-site infection. Blood cultures confirmed methicillin-susceptible S. aureus bacteremia consistent with a catheter-related source. The diagnosis of secondary acute bacterial meningitis was confirmed by cerebrospinal fluid analysis and culture. Despite prompt initiation of empirical antimicrobial therapy, de-escalation to targeted anti-staphylococcal therapy, and catheter removal, the patient's condition rapidly deteriorated, and the patient died of refractory septic shock. This case highlights the aggressive progression and high mortality associated with S. aureus CRBSI complicated by hematogenous meningitis in immunocompromised patients and illustrates the importance of early recognition, prompt microbiological diagnosis, immediate source control, and vigilant clinical monitoring following catheter placement.

Для цитирования: Benoumrhar Youssef, Khlifi Tagzouti Nada, El Kamouni Youssef, Zouhair Said, Arsalane Lamiae. A Rare Case of Methicillin-Susceptible Staphylococcus aureus Catheter-Related Bloodstream Infection Complicated by Acute Bacterial Meningitis and Refractory Septic Shock in Morocco: A Case Report.. Cureus. 2026. DOI: 10.7759/cureus.108432.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.