MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10620-019-05882-2

Медицинская библиотека · Digestive diseases and sciences · 2019

When Experts Fail: Use of a Short Turning Radius Colonoscope Facilitates Successful Completion of Colonoscopy in Patients with Bowel Fixity.

Girotra Mohit, Sethi Saurabh, Barakat Monique T, Huang Robert J, Friedland Shai, Ladabaum Uri, Banerjee Subhas

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Rates of incomplete colonoscopy in non-expert settings range up to 13%. Expert colonoscopists can complete ~ 95% colonoscopies when other endoscopists fail; however, a small number remain incomplete even in expert hands, typically due to bowel fixity.

AIMS: Pentax Retroview™ (EC-3490TLi) is a new slim colonoscope with a short turning radius (STR) and greater tip deflection (210°), which allows easy maneuverability across sharply angulated/fixed colonic bends. We evaluated the utility of this colonoscope for completing colonoscopies that fail even in the hands of expert colonoscopists.

METHODS

Retrospective chart review was performed, and main outcomes measured included cecal intubation rate, lesions detected, dosage of sedation used, and complications.

RESULTS

Using the STR colonoscope, complete colonoscopy to the cecum was possible in 34/37 patients (91.9%). No loss of lumen/blind advancement was necessary in any of the procedures. No adverse events occurred. Among the completed colonoscopies, 6/34 (17.6%) patients had adenomas, all proximal to the site of prior failure, including one advanced adenoma. All failures (n = 3, 8.1%) had a history of cancer surgeries, with peritoneal carcinomatosis/extensively fixed/frozen bowel (two patients) and an additional diverticular stricture with colo-vesical fistula (one patient).

CONCLUSION

STR colonoscope facilitates completion of a high proportion (91.9%) of colonoscopies that previously failed in expert hands. Its STR allows easy maneuverability across segments of sharp angulation with bowel fixity without need for blind advancement. The use of this colonoscope led to the detection of adenomas in 17.6% of patients, all proximal to the site of prior failed colonoscopy.

Для цитирования: Girotra Mohit, Sethi Saurabh, Barakat Monique T, Huang Robert J, Friedland Shai, Ladabaum Uri, Banerjee Subhas. When Experts Fail: Use of a Short Turning Radius Colonoscope Facilitates Successful Completion of Colonoscopy in Patients with Bowel Fixity.. Digestive diseases and sciences. 2019. DOI: 10.1007/s10620-019-05882-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.