Localized delivery of compounds into articular cartilage by using high-intensity focused ultrasound.

Nieminen Heikki J, Lampsijärvi Eetu, Barreto Gonçalo, Finnilä Mikko A J, Salmi Ari, Airaksinen Anu J, Eklund Kari K, Saarakkala Simo, Pritzker Kenneth P H, Hæggström Edward

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Localized delivery of drugs into an osteoarthritic cartilaginous lesion does not yet exist, which limits pharmaceutical management of osteoarthritis (OA). High-intensity focused ultrasound (HIFU) provides a means to actuate matter from a distance in a non-destructive way. In this study, we aimed to deliver methylene blue locally into bovine articular cartilage in vitro. HIFU-treated samples (n = 10) were immersed in a methylene blue (MB) solution during sonication (f = 2.16 MHz, peak-positive-pressure = 3.5 MPa, mechanical index = 1.8, pulse repetition frequency = 3.0 kHz, cycles per burst: 50, duty cycle: 7%). Adjacent control 1 tissue (n = 10) was first pre-treated with HIFU followed by immersion into MB; adjacent control 2 tissue (n = 10) was immersed in MB without ultrasound exposure. The MB content was higher (p < 0.05) in HIFU-treated samples all the way to a depth of 600 µm from AC surface when compared to controls. Chondrocyte viability and RNA expression levels associated with cartilage degeneration were not different in HIFU-treated samples when compared to controls (p > 0.05). To conclude, HIFU delivers molecules into articular cartilage without major short-term concerns about safety. The method is a candidate for a future approach for managing OA.

Для цитирования: Nieminen Heikki J, Lampsijärvi Eetu, Barreto Gonçalo, Finnilä Mikko A J, Salmi Ari, Airaksinen Anu J, Eklund Kari K, Saarakkala Simo, Pritzker Kenneth P H, Hæggström Edward. Localized delivery of compounds into articular cartilage by using high-intensity focused ultrasound.. Scientific reports. 2019. DOI: 10.1038/s41598-019-52012-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.