Transperineal Sonography and Urodynamic Findings in Women With Lower Urinary Tract Symptoms After Sling Placement.

Takacs Peter, Larson Kindra, Scott Lauren, Cunningham Tina D, DeShields Sarah C, Abuhamad Alfred

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate dynamic 2-dimensional (2D) transperineal pelvic sonographic findings and urodynamic studies in women with lower urinary tract symptoms after midurethral sling placement.

METHODS

Transperineal pelvic sonography and urodynamic studies were reviewed from women with a midurethral sling and lower urinary tract symptoms. The shape and sonographic dynamic change of the sling from the rest position to the maximum Valsalva maneuver and back to rest were recorded. Patients were categorized into 3 groups: group I, at rest, the sling lies parallel to the urethral lumen, and during Valsalva, the sling becomes C shaped; group 2, both at rest and during Valsalva, the sling runs parallel to the urethral lumen; and group 3, at rest, the sling is C shaped, and during Valsalva, this curved shape is maintained. For analytical purposes group 3 was compared with groups 1 and 2. Multiple logistic regressions were used to evaluate the association between transperineal pelvic sonography and urodynamic studies.

RESULTS

Seventy-seven women were enrolled. The detrusor pressure at the maximum flow rate was significantly higher in group 3 than groups 1 and 2 (mean ± SD, 36 ± 16 versus 19 ± 11 mm H2 O; P < .001). The odds of high detrusor pressure (>20 mm H2 O) in group 3 was approximately 12 times the odds of those in groups 1 and 2. After adjusting for other variables using a multiple logistic regression analysis, a statistically significant association between group 3 and high detrusor pressure persisted (odds ratio, 29.7; 95% confidence interval, 2.949-299.6; P = .0040) persisted.

CONCLUSIONS

Transperineal dynamic 2D sonography can help predict women with high-pressure voiding after midurethral sling placement and aid in the diagnosis of bladder outlet obstruction.

Для цитирования: Takacs Peter, Larson Kindra, Scott Lauren, Cunningham Tina D, DeShields Sarah C, Abuhamad Alfred. Transperineal Sonography and Urodynamic Findings in Women With Lower Urinary Tract Symptoms After Sling Placement.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2016. DOI: 10.7863/ultra.16.02076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.