Impact of insertion site on complications in central venous access devices.

Mansfield Sara A, Staszak Jessica, Murphy Andrew J, Talbot Lindsay, Abdelhafeez Abdelhafeez, Prajapati Hasmukh, Gold Robert, Maller Vinod, Proctor Kimberly, Davidoff Andrew M, Williams Regan F

СтатьяПеревод в очереди

Аннотация

PURPOSE: There is still debate over the safest route for the placement of long-term central venous access devices. The aim of this study was to review a large, single-institution experience to determine the impact of access location on peri-operative complications.

METHODS

The records of patients undergoing subcutaneous port (SQP) and tunneled catheter insertion over a seven-year period were reviewed. Vein cannulated (subclavian (SCV) versus internal jugular (IJ) vein), and 30-day complications were assessed. Surgical complications included pneumothorax, hemothorax, infections, arrhythmia or malpositioning requiring intervention.

RESULTS

A total of 1,309 patients were included (618 SQP, 691 tunneled catheters). The location for insertion was SCV (909, 69.4%) and IJ (400, 30.6%). There were 69 complications (5.2%) (41, 4.5% SCV, 28, 7.0% IJV) including: malpositioning/malfunctioning (SCV 13, 1.4% and IJV 14, 3.0%), pneumothorax (SCV 4, 0.4% and IJV 1, 0.3%), hemothorax (SCV 0 and IJV 1, 0.3%), arrhythmia (SCV 1, 0.1%, and IJV 0), and infection within 30 days of placement (SCV 20, 2.2% and IJ 11, 2.8%). The complication rates were not significantly different based on site (p = 0.080).

CONCLUSION

There was no significant difference in complication rates when using the subclavian versus the internal jugular vein as the site for long-term central venous access.

LEVEL OF EVIDENCE: III, retrospective comparative study.

Для цитирования: Mansfield Sara A, Staszak Jessica, Murphy Andrew J, Talbot Lindsay, Abdelhafeez Abdelhafeez, Prajapati Hasmukh, Gold Robert, Maller Vinod, Proctor Kimberly, Davidoff Andrew M, Williams Regan F. Impact of insertion site on complications in central venous access devices.. Pediatric surgery international. 2023. DOI: 10.1007/s00383-023-05399-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.