MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjhci-2024-101427

Медицинская библиотека · BMJ health & care informatics · 2025

Feasibility of semiautomated surveillance of healthcare-associated Staphylococcus aureus bloodstream infections using hospital electronic health records in Victoria, Australia.

Lim Lyn-Li, Tanamas Stephanie K, Bull Ann, Capurro Daniel, Snook Kylie, Leung Vivian K Y, Friedman N Deborah, Marshall Caroline, Laguitan Roland, Brett Judy, Worth Leon J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Many hospitals struggle to transform electronic health record (EHR) data to support performance, continuous improvement and patient safety. Our study aimed to explore the feasibility of semiautomated surveillance for healthcare-associated infections (HAIs) in Australian hospitals, focussing on Staphylococcus aureus bloodstream infection (SABSI) surveillance.

METHOD: National surveillance case definitions were reviewed with an inventory list of data elements created to identify high-probability healthcare-associated SABSI events. An interview schedule was developed to assess the availability, characteristics and quality of EHR data for data elements. Interviews were conducted with hospital infection prevention and control (IPC) staff.

RESULTS

12 IPC staff representing 12 hospitals and 11 healthcare organisations were interviewed. EHRs were in place at nine (75%) sites, supplied by six different vendors. Heterogeneity was observed in EHR functionalities, data capture methods for routine care and local approaches to use electronic systems to reduce HAI surveillance workload. None reported using automated surveillance systems. Most core data elements for the SABSI algorithm were present in EHRs, suggesting only minor modification to the SABSI definitions may be needed for automation, but issues with data quality were also described.

DISCUSSION: We propose that modification of the national SABSI definitions is needed for automation. While many Victorian hospitals have adopted EHRs, data quality and interoperability issues limit the leveraging of EHR data for secondary purposes.

CONCLUSIONS

We have taken the initial steps of evaluating the feasibility of semiautomated HAI surveillance in Victorian hospitals. With further development, this offers the promise of enhanced efficiency and reduced human resources required for HAI surveillance.

Для цитирования: Lim Lyn-Li, Tanamas Stephanie K, Bull Ann, Capurro Daniel, Snook Kylie, Leung Vivian K Y, Friedman N Deborah, Marshall Caroline, Laguitan Roland, Brett Judy, Worth Leon J. Feasibility of semiautomated surveillance of healthcare-associated Staphylococcus aureus bloodstream infections using hospital electronic health records in Victoria, Australia.. BMJ health & care informatics. 2025. DOI: 10.1136/bmjhci-2024-101427.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.