Discrimination of spontaneous activity in needle EMG based on the quantitative assessment of the discharge rhythm using "Random Index".

Mukai Taiji, Kanbayashi Takamichi, Kobayashi Masahito, Okano Masamichi Peter, Tachiyama Keisuke, Miyaji Yosuke, Hatanaka Yuki, Kobayashi Shunsuke, Sonoo Masahiro

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Discrimination between EMG activity such as fibrillation potentials/positive sharp waves (Fib/PSW), end plate spikes (EPS), fasciculation potentials (FP), and contaminating voluntary motor unit potentials (MUP) is mandatory for EMG diagnosis. Discharge rhythm is the key for discrimination. We devised a new parameter, Random Index (RI), which quantifies the rhythm and takes a value from 0 to 1, smaller for regular trains of discharges. This study evaluated the utility of RI as well as modified versions of the regularity indices proposed in past reports.

METHODS

EMG records of patients with amyotrophic lateral sclerosis were retrospectively reviewed. EPS were collected also from a healthy volunteer. The EMG activity was classified by an expert. RI and other regularity indices as well as the median instantaneous firing rate (IFRm) were calculated.

RESULTS

Analyzed sequences were 73 Fib/PSW, 27 EPS, 24 FP, and 36 MUP. The four types were clearly separated over the 2-dimensional plots of regularity indices vs. IFRm. Especially, Fib/PSW and EPS were far separated in these plots. RI achieved significantly better discrimination between Fib/PSW and MUP than other indices.

CONCLUSION

RI is a robust tool for discriminating EMG activity.

SIGNIFICANCE: RI and other regularity indices would be useful for educational purpose.

Для цитирования: Mukai Taiji, Kanbayashi Takamichi, Kobayashi Masahito, Okano Masamichi Peter, Tachiyama Keisuke, Miyaji Yosuke, Hatanaka Yuki, Kobayashi Shunsuke, Sonoo Masahiro. Discrimination of spontaneous activity in needle EMG based on the quantitative assessment of the discharge rhythm using "Random Index".. Clinical neurophysiology practice. 2026. DOI: 10.1016/j.cnp.2026.01.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.