MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2022.02.051

Медицинская библиотека · The Annals of thoracic surgery · 2022

Palliation Plus Ventricular Assist Device Insertion in 15 Neonates and Infants With Functionally Univentricular Circulation.

Bleiweis Mark S, Philip Joseph, Peek Giles J, Fudge James C, Sullivan Kevin J, Co-Vu Jennifer, Gupta Dipankar, Shih Renata, Pietra Biagio Bill A, Fricker Frederick Jay, Vyas Himesh V, Hernandez-Rivera Jose F, Powers Emma R, Nixon Connie S, Falasa Matheus, Jacobs Jeffrey Phillip

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We report 15 high-risk neonates and infants with functionally univentricular circulation stabilized with initial surgical palliation plus ventricular assist device (VAD) insertion (PALLIATION+VAD) in preparation for transplantation.

METHODS

Fifteen functionally univentricular patients with ductal-dependent systemic circulation (8 hypoplastic left heart syndrome, 1 hypoplastic left heart syndrome-related malformation: 7 neonates, 2 infants) or ductal-dependent pulmonary circulation (6 hypoplastic right heart syndrome: 5 neonates, 1 infant) presented with anatomical and/or physiological features associated with increased risk for conventional univentricular palliation (large coronary sinusoids with ventricular-dependent coronary circulation, severe systemic atrioventricular valvar regurgitation, cardiogenic shock, or restrictive atrial septum). PALLIATION+VAD for patients with ductal-dependent systemic circulation was: VAD insertion plus application of bilateral pulmonary bands, stent placement in the arterial duct, and atrial septectomy, if needed. PALLIATION+VAD for patients with ductal-dependent pulmonary circulation was: VAD insertion plus stent placement in the arterial duct or systemic-to-pulmonary artery shunt with pulmonary arterioplasty, if needed.

RESULTS

At PALLIATION+VAD, median age was 20 days (range, 4-143 days) and median weight was 3.47 kg (range, 2.43-4.86 kg). Ten patients (67%) survived and 5 patients (33%) died. All ten survivors are at home doing well after successful transplantation. Only 2 of 10 survivors (20%) required intubation >10 days after PALLIATION+VAD. Median length of VAD support for all 15 patients was 138 days (range, 56-226 days).

CONCLUSIONS

High-risk neonates with functionally univentricular hearts who are suboptimal candidates for conventional palliation can be successfully stabilized with pulsatile VAD insertion along with initial palliation while awaiting cardiac transplantation; these patients may be extubated, enterally nourished, and optimized for transplantation while on VAD.

Для цитирования: Bleiweis Mark S, Philip Joseph, Peek Giles J, Fudge James C, Sullivan Kevin J, Co-Vu Jennifer, Gupta Dipankar, Shih Renata, Pietra Biagio Bill A, Fricker Frederick Jay, Vyas Himesh V, Hernandez-Rivera Jose F, Powers Emma R, Nixon Connie S, Falasa Matheus, Jacobs Jeffrey Phillip. Palliation Plus Ventricular Assist Device Insertion in 15 Neonates and Infants With Functionally Univentricular Circulation.. The Annals of thoracic surgery. 2022. DOI: 10.1016/j.athoracsur.2022.02.051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.