Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2023
Outcome and Complications following Stabilization of Coxofemoral Luxations in Cats Using a Modified Hip Toggle Stabilization-A Retrospective Multicentre Study.
Многоцентровое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Knell Sebastian Christoph, Longo Federico, Wolfer Nadja, Schmierer Philipp A, Hermann Andreas, Pozzi Antonio
Аннотация
OBJECTIVES: The main aim of this study was to report the surgical technique, the complications and the clinical outcomes of the mini-Tight Rope system (mini-TR) for a modified hip toggle stabilization of coxofemoral luxation in cats.
STUDY DESIGN: A multicentre retrospective study.
ANIMALS: Thirty-two client-owned cats.
METHODS: Medical records (2009-2017) of cats, which underwent stabilization of a coxofemoral luxation with the mini-TR and had at least a 3-month follow-up, were reviewed. The femoral tunnel diameter, the use of one or two FiberWire loops, perioperative complications and clinical outcomes were recorded. Follow-up information was obtained through clinical and radiographic examinations and an owner questionnaire.
RESULTS: Thirty-two cats met the inclusion criteria. Concurrent injuries were present in 16 cats. A single or double loop mini-TR was used in 21 and 12 cats respectively. One double loop (1/12 cats) and four single loop (4/16 cats) sutures failed. Moderate-to-severe coxofemoral osteoarthritis developed in 14/27 cats. Owner questionnaires revealed excellent clinical outcomes.
CLINICAL SIGNIFICANCE: Mini-TR with a double-stranded implant is recommended to decrease the risk of suture failure. Osteoarthritis is common after open reduction of hip luxations.
STUDY DESIGN: A multicentre retrospective study.
ANIMALS: Thirty-two client-owned cats.
METHODS: Medical records (2009-2017) of cats, which underwent stabilization of a coxofemoral luxation with the mini-TR and had at least a 3-month follow-up, were reviewed. The femoral tunnel diameter, the use of one or two FiberWire loops, perioperative complications and clinical outcomes were recorded. Follow-up information was obtained through clinical and radiographic examinations and an owner questionnaire.
RESULTS: Thirty-two cats met the inclusion criteria. Concurrent injuries were present in 16 cats. A single or double loop mini-TR was used in 21 and 12 cats respectively. One double loop (1/12 cats) and four single loop (4/16 cats) sutures failed. Moderate-to-severe coxofemoral osteoarthritis developed in 14/27 cats. Owner questionnaires revealed excellent clinical outcomes.
CLINICAL SIGNIFICANCE: Mini-TR with a double-stranded implant is recommended to decrease the risk of suture failure. Osteoarthritis is common after open reduction of hip luxations.