MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000033328

Медицинская библиотека · Medicine · 2023

Effect of patient characteristics on vessel enhancement on arterio-venous fistula CT angiography in a retrospective cohort study.

Masuda Takanori, Nakaura Takeshi, Funama Yoshinori, Sato Tomoyasu, Masuda Shouko, Yoshiura Takayuki, Gotanda Rumi, Arao Keiko, Imaizumi Hiromasa, Arao Shinichi, Ono Atsushi, Hiratsuka Junichi, Awai Kazuo

СтатьяПеревод в очереди

Аннотация

To evaluate the effects of various patient characteristics on vessel enhancement on arterio-venous fistula (AVF) computed tomography (CT) angiography (AVF-CT angiography). A total of 127 patients with suspected or confirmed shunt stenosis and internal AVF complications were considered for inclusion in a retrospective cohort study. The tube voltage was 120 kVp, and the tube current was changed from 300 to 770 mA to maintain the image quality (noise index: 14) using automatic tube current modulation. To evaluate the effects of age, sex, body size, and scan delay on the CT number of the brachial artery or vein, we used correlation coefficients and multivariate regression analyses. There was a significant positive correlation between the CT number of the brachial artery or vein and age (R = 0.21 or 0.23, P < .01). The correlations were inverse with the height (r = -0.45 or -0.42), total body weight (r = -0.52 or -0.50), body mass index (r = -0.21 or -0.23), body surface area (body surface area [BSA]; r = -0.56 or -0.54), and lean body weight (r = -0.55 or -0.53) in linear regression analysis (P < .01 for all). There was a significant correlation between the CT number of the brachial artery or vein and scan delay (R = 0.19 or 01.9, P < .01). Only the BSA had significant effects on the CT number in multivariate regression analysis (P < .01). The BSA was significantly correlated with the CT number of the brachial artery or vein on AVF-CT angiography.

Для цитирования: Masuda Takanori, Nakaura Takeshi, Funama Yoshinori, Sato Tomoyasu, Masuda Shouko, Yoshiura Takayuki, Gotanda Rumi, Arao Keiko, Imaizumi Hiromasa, Arao Shinichi, Ono Atsushi, Hiratsuka Junichi, Awai Kazuo. Effect of patient characteristics on vessel enhancement on arterio-venous fistula CT angiography in a retrospective cohort study.. Medicine. 2023. DOI: 10.1097/md.0000000000033328.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.