MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10096-024-04868-x

Медицинская библиотека · European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2024

Multiplex microarray PCR Unyvero BCU system to accelerate relevant antimicrobial treatment in polymicrobial bloodstream infection.

Bonnefoy C, Vannini M, Degand N, Gaudart A, Lotte R, Buisson-Touati C, Ruimy R, Lamy B

СтатьяОценочное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate the performance of a rapid multiplex microarray-based method (Unyvero BCU system, BCU) to identify microorganisms and detect antimicrobial resistance directly from positive blood culture (BC) bottles with polymicrobial growth, and to assess relevance of information provided for timely guidance of polymicrobial bloodstream infection treatment.

METHODS

Accuracy, time-to-actionable results and potential impact of BCU on antimicrobial treatment were compared with those of standard of care during a prospective study for the sample analysis (November 2017-November 2018) and a retrospective study for the clinical data analysis and the time-to-result analysis. The study was complemented with an experimental study, based on spiked blood cultures to assess the ability of the method to detect antimicrobial resistance genes.

RESULTS

Sixty-five clinical polymicrobial BC samples (163 total microorganisms) and 30 simulated polymicrobial BC samples (60 strains) were included. BCU reported 84.6% samples as polymicrobial, correctly identified all the bacteria of the mix for 72.3% samples (47/65) and detected bacteria that were missed by the conventional culture for 13.8% samples. All identifications and antimicrobial resistances were accurately detected for 61.5% (40/65) samples. Limitations concerned the detection of anaerobes, enterococci and enterobacterial susceptibility to third generation cephalosporins. BCU results would have guided antimicrobial treatment for 50.8% of the cases (33/65) in a timely and relevant manner, had no impact for 27.7% (18/65) and been misleading for 18.5% (12/65).

CONCLUSIONS

Despite some limitations, the Unyvero BCU system is a rapid and reliable method for polymicrobial BC sample analysis.

Для цитирования: Bonnefoy C, Vannini M, Degand N, Gaudart A, Lotte R, Buisson-Touati C, Ruimy R, Lamy B. Multiplex microarray PCR Unyvero BCU system to accelerate relevant antimicrobial treatment in polymicrobial bloodstream infection.. European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology. 2024. DOI: 10.1007/s10096-024-04868-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.