MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e31819aa9d9

Медицинская библиотека · Cornea · 2009

Occult open globe injury in a patient with corneal foreign body: a case report.

Kah Tan Aik, Salowi Mohamad Aziz, Tagal Julian Matius, Thanaraj Asokumaran, Premsenthil Mallika, Gudom Intan ak

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: To demonstrate the role of ultrasonographic biomicroscopy in diagnosing occult open globe injury.

METHOD: A 50-year old man presented with a 2-day history of a corneal foreign body caused by a missile injury. Slit lamp biomicroscopy showed an intrastromal corneal foreign body measuring 0.7 x 0.7 mm, situated at the visual axis. Seidel test was negative. Full thickness corneal penetration could not be ruled out and an ultrasonographic biomicroscopy examination was subsequently performed.

RESULTS

Ultrasonographic biomicroscopy revealed a probable full thickness corneal penetration. The patient was diagnosed with penetrating corneal injury.

CONCLUSION

Ultrasonographic biomicroscopy has an important role in the diagnosis of occult open globe injury.

Для цитирования: Kah Tan Aik, Salowi Mohamad Aziz, Tagal Julian Matius, Thanaraj Asokumaran, Premsenthil Mallika, Gudom Intan ak. Occult open globe injury in a patient with corneal foreign body: a case report.. Cornea. 2009. DOI: 10.1097/ico.0b013e31819aa9d9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.