DOI 10.1016/j.carrev.2022.08.025
Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis With a Severely Calcified Raphe Using An Under-Sized SAPIEN 3 Valve: Sizing by the Circle Method and Deployment by the Pressure-Regulated Method.
Аннотация
Transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve stenosis is challenging, and the absence of established methods for sizing the bicuspid aortic valve (BAV) complicates TAVR. We report a case of successful TAVR for bicuspid aortic stenosis with a severely calcified raphe. We used an undersized SAPIEN 3 valve, with three safety measures based on assessment of structural characteristics, sizing by the circle method, and deployment of the valve by the pressure-regulated method.