Midterm Outcomes of Endovascular Repair of Aortic Arch Aneurysms with the Gore Thoracic Branch Endoprosthesis.

Liang Nathan L, Dake Michael D, Fischbein Michael P, Bavaria Joseph E, Desai Nimesh D, Oderich Gustavo S, Singh Michael J, Fillinger Mark, Suckow Bjoern D, Matsumura Jon S, Patel Himanshu J, Makaroun Michel S

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Aortic aneurysms involving aortic arch vessels are anatomically unsuitable for standard thoracic endovascular repair (TEVAR) without cervical debranching of the arch vessels. Three year outcomes of a single branched thoracic endograft following previous publication of peri-operative and one year outcomes are reported.

METHODS

This was a multicentre feasibility trial of the GORE TAG Thoracic Branch Endoprosthesis (TBE), a thoracic endovascular graft incorporating a single retrograde branch for aortic arch vessel perfusion. The first study arm enrolled patients with an intact descending thoracic aortic aneurysm extending to the distal arch with left subclavian artery (LSA) incorporation (zone 2). The second arm enrolled patients with arch aneurysms requiring incorporation of the left carotid or innominate artery (zone 0/1) and extra-anatomic surgical revascularisation of the remaining aortic arch vessels. Outcomes at three years are reported.

RESULTS

The cohort comprised 40 patients (31 zone 2, nine zone 0/1). The majority were male (52%). Mean follow up was 1 408 ± 552 days in the zone 2 and 1 187 ± 766 days in the zone 0/1 cohort. During three year follow up there was no device migration, fracture, or aortic rupture in either arm. In the zone 2 arm, freedom from re-intervention was 97% at one and three years but there were two side branch occlusions. Two patients had aneurysm enlargement > 5 mm without documented endoleak or re-intervention. Freedom from death at one and three years was 90% and 84%. In the zone 0/1 arm there were no re-interventions, loss of branch patency, or aneurysm enlargement at three years. Cerebrovascular events occurred in three patients during follow up: two unrelated to the device or procedure, and one of unknown relationship. Two patients in this arm died during the follow up period, both unrelated to the procedure or the aneurysm.

CONCLUSION

Initial three year results of the TBE device for endovascular repair of arch aneurysms show favourable patency and durability with low rates of graft related complications.

Для цитирования: Liang Nathan L, Dake Michael D, Fischbein Michael P, Bavaria Joseph E, Desai Nimesh D, Oderich Gustavo S, Singh Michael J, Fillinger Mark, Suckow Bjoern D, Matsumura Jon S, Patel Himanshu J, Makaroun Michel S. Midterm Outcomes of Endovascular Repair of Aortic Arch Aneurysms with the Gore Thoracic Branch Endoprosthesis.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 2022. DOI: 10.1016/j.ejvs.2022.08.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.