MedElevator Войти в исследования
← Поиск публикаций

DOI 10.11152/mu-4539

Медицинская библиотека · Medical ultrasonography · 2025

Diagnostic capabilities for Müllerian anomalies in women with reproductive disorders.

Chapidze Ia, Kristesashvili Jenaro, Kutateladze Mariam, Matitashvili Sergo

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

AIM: To determine the frequency and types of Müllerian anomalies (MA) in women with various reproductive disorders and demonstrate three-dimensional transvaginal ultrasound's (3D TVUS) capabilities in MA diagnosis.

MATERIAL AND

METHODS

A prospective, comparative, case-control study was conducted on 3,973 women aged 16 to 45 between 2019 and 2023. Among them, 2,394 women had primary infertility (Group I), 898 - recurrent pregnancy losses (Group II), 61 - primary amenorrhea (Group III), and 620 women with one or more full-term live births constituted control group (Group IV). All women underwent 2D TVUS and 3D TVUS examinations. Additionally, hysterosalpingography was conducted on 49 women, hystero-laparoscopy on 53 women, and magnetic resonance imaging (MRI) on 30 women.

RESULTS

The most common MA identified in Group I and Group II was a septate uterus. In diagnosing this condition, the 3D TVUS demonstrated sensitivity of 95.83% and specificity of 100% compared to MRI, with Kappa index of 0.978. Compared to hystero-laparoscopy, 3D TVUS exhibited sensitivity of 97.5% and specificity of 100%, with Kappa index of 0.987. Compared to hysterosalpingography, MRI, and hystero-laparoscopy, the 3D TVUS showed 100% sensitivity and specificity for all other anomalies.

CONCLUSION

Three-dimentional ultrasonography is a rapid, cost-effective, non-invasive, and highly informative method for evaluating Müllerian anomalies. It demonstrated good concordance with the magnetic resonance imaging method.

Для цитирования: Chapidze Ia, Kristesashvili Jenaro, Kutateladze Mariam, Matitashvili Sergo. Diagnostic capabilities for Müllerian anomalies in women with reproductive disorders.. Medical ultrasonography. 2025. DOI: 10.11152/mu-4539.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.