18F-FDG PET/CT in left ventricular assist device infections: In-depth characterization and clinical implications.

Devesa Ana, Rashed Eman, Moss Noah, Robson Philip M, Pyzik Renata, Roldan Julie, Taimur Sarah, Rana Meenakshi M, Ashley Kimberly, Young Anna, Patel Gopi, Mahmood Kiran, Mitter Sumeet S, Lala Anuradha, Barghash Maya, Fox Arieh, Correa Ashish, Pirlamarla Preethi, Contreras Johanna, Parikh Aditya, Mancini Donna, Jacobi Adam, Ghesani Nasrin, Gavane Somali C, Ghesani Munir, Itagaki Shinobu, Anyanwu Anelechi, Fayad Zahi A, Trivieri Maria Giovanna

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Previous retrospective studies suggest a good diagnostic performance of 18F-fluorodeoxyglucose positron emission tomography (18F-FDG-PET)/computed tomography (CT) in left ventricular assist device (LVAD) infections. Our aim was to prospectively evaluate the role of PET/CT in the characterization and impact on clinical management of LVAD infections.

METHODS

A total of 40 patients (aged 58 [53-62] years) with suspected LVAD infection and 5 controls (aged 69 [64-71] years) underwent 18F-FDG-PET/CT. Four LVAD components were evaluated: exit site and subcutaneous driveline (peripheral), pump pocket, and outflow graft. The location with maximal uptake was considered the presumed site of infection. Infection was confirmed by positive culture (exit site or blood) and/or surgical findings.

RESULTS

Visual uptake was present in 40 patients (100%) in the infection group vs 4 (80%) control subjects. For each individual component, the presence of uptake was more frequent in the infection than in the control group. The location of maximal uptake was most frequently the pump pocket (48%) in the infection group and the peripheral components (75%) in the control group. Maximum standard uptake values (SUVmax) were higher in the infection than in the control group: SUVmax (average all components): 6.9 (5.1-8.5) vs 3.8 (3.7-4.3), p = 0.002; SUVmax (location of maximal uptake): 10.6 ± 4.0 vs 5.4 ± 1.9, p = 0.01. Pump pocket infections were more frequent in patients with bacteremia than without bacteremia (79% vs 31%, p = 0.011). Pseudomonas (32%) and methicillin-susceptible Staphylococcus aureus (29%) were the most frequent pathogens and were associated with pump pocket infections, while Staphylococcus epidermis (11%) was associated with peripheral infections. PET/CT affected the clinical management of 83% of patients with infection, resulting in surgical debridement (8%), pump exchange (13%), and upgrade in the transplant listing status (10%), leading to 8% of urgent transplants.

CONCLUSIONS

18F-FDG-PET/CT enables the diagnosis and characterization of the extent of LVAD infections, which can significantly affect the clinical management of these patients.

Для цитирования: Devesa Ana, Rashed Eman, Moss Noah, Robson Philip M, Pyzik Renata, Roldan Julie, Taimur Sarah, Rana Meenakshi M, Ashley Kimberly, Young Anna, Patel Gopi, Mahmood Kiran, Mitter Sumeet S, Lala Anuradha, Barghash Maya, Fox Arieh, Correa Ashish, Pirlamarla Preethi, Contreras Johanna, Parikh Aditya, Mancini Donna, Jacobi Adam, Ghesani Nasrin, Gavane Somali C, Ghesani Munir, Itagaki Shinobu, Anyanwu Anelechi, Fayad Zahi A, Trivieri Maria Giovanna. 18F-FDG PET/CT in left ventricular assist device infections: In-depth characterization and clinical implications.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2023. DOI: 10.1016/j.healun.2023.11.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.