MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jconrel.2026.114897

Медицинская библиотека · Journal of controlled release : official journal of the Controlled Release Society · 2026

A versatile hernia mesh for abdominal wall reconstruction with fibrosis suppression and non-invasive monitoring capabilities.

Xiao Yelei, Zhou Sirong, Wu Yanheng, Ma Yamei, Mei Jinghao, Yang Wei, Yang Chun, Cai Lulu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Postoperative recurrence after incisional hernia repair remains a significant clinical challenge, with mesh contraction from the fibrotic foreign body response as an important contributing factor. Meanwhile, the inherent radiolucency of standard polypropylene (PP) meshes hinders postoperative imaging assessment. To address this, we developed a versatile mesh, SB431542@MPDA-PP, by functionalizing a medical-grade PP mesh with mesoporous polydopamine (MPDA) nanoparticles for localized drug delivery and intrinsic photoacoustic (PA) imaging. The mesh achieved high encapsulation loading (97.13%) and sustained release of SB431542, a TGF-β receptor inhibitor. It suppressed TGF-β1 secretion, epithelial-mesenchymal transition (EMT), and pro-fibrotic responses in human peritoneal mesothelial cells in vitro. In a rat model, the mesh reduced contraction by approximately 47.4% at 3 months compared to standard PP, with attenuated collagen deposition and a favorable collagen I/III ratio. Mechanistically, SB431542 release inhibited the TGF-β1/Smad axis, reversed EMT, and suppressed myofibroblast activation. Furthermore, the MPDA coating enabled clear, non-invasive PA visualization (>96% compliance). This integrated platform simultaneously mitigates fibrosis and enables postoperative surveillance, offering a promising strategy to improve hernia repair outcomes.

Для цитирования: Xiao Yelei, Zhou Sirong, Wu Yanheng, Ma Yamei, Mei Jinghao, Yang Wei, Yang Chun, Cai Lulu. A versatile hernia mesh for abdominal wall reconstruction with fibrosis suppression and non-invasive monitoring capabilities.. Journal of controlled release : official journal of the Controlled Release Society. 2026. DOI: 10.1016/j.jconrel.2026.114897.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.