MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcu.70075

Медицинская библиотека · Journal of clinical ultrasound : JCU · 2025

Is Middle Cerebral Artery Doppler a Reliable Tool for Fetal Monitoring? A Prospective Observational Study on Intra and Inter-Observer Variability.

Masini Giulia, Gizzi Alessandra, Ponziani Ilaria, Spataro Elisa, Seravalli Viola, Pasquini Lucia

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: Evaluation of intra- and inter-observer variability of middle cerebral artery (MCA) pulsatility index (PI) in pregnancies complicated by fetal growth restriction (FGR) compared to normally grown controls and literature review.

METHODS

Prospective observational cross-sectional study. Singleton pregnancies between 26 and 40 weeks were included and divided into two groups based on fetal growth: fetal growth restricted and normally grown fetuses. Fetal growth restricted fetuses were divided into early and late FGR. Intra-and inter-observer variability were assessed by Intraclass Correlation Coefficient (ICC) and interpreted following the TRUST criteria and GRRAS guidelines.

RESULTS

One hundred and fifty patients were included in the study. Forty-eight cases were complicated by FGR: 27 early-onset and 21 late-onset. 13/48 (27%) showed middle cerebral artery redistribution. Intra and interobserver reproducibility were "poor" in the appropriate for gestational age (AGA) fetuses. In the FGR group, the intraobserver reproducibility was "moderate" and interobserver reproducibility was "moderate/poor". Intraobserver reproducibility was "good" in early FGR and "moderate" in late FGR cases, while interobserver reproducibility was "moderate" in early FGR and "poor" in late FGR cases.

CONCLUSION

MCA PI Doppler repeatability is superior in FGR fetuses compared to AGA fetuses. MCA pulsatility index can be used with confidence in FGR, especially if early onset.

Для цитирования: Masini Giulia, Gizzi Alessandra, Ponziani Ilaria, Spataro Elisa, Seravalli Viola, Pasquini Lucia. Is Middle Cerebral Artery Doppler a Reliable Tool for Fetal Monitoring? A Prospective Observational Study on Intra and Inter-Observer Variability.. Journal of clinical ultrasound : JCU. 2025. DOI: 10.1002/jcu.70075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.