MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2024.04.054

Медицинская библиотека · Heart rhythm · 2024

Transvenous extraction of conduction system pacing leads: An international multicenter (TECSPAM) study.

Vijayaraman Pugazhendhi, Trivedi Rohan S, Koneru Jayanthi N, Sharma Parikshit S, De Pooter Jan, Schaller Robert D, Cano Óscar, Whinnett Zachary I, Migliore Federico, Ponnusamy Shunmuga Sundaram, Skeete Jamario R, Zanon Francesco, Heuverswyn Frederic V, Kolominsky Jeffrey, Pittorru Raimondo, Mumtaz Mishal, Ellenbogen Kenneth A, Herweg Bengt

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Conduction system pacing (CSP) by His bundle pacing or left bundle branch area pacing (LBBAP) is incorporated into Heart Rhythm Society guidelines for the management of bradycardia and cardiac resynchronization therapy. Despite increasing adoption with both lumenless leads and stylet-driven leads, concerns regarding the feasibility and safety of the extraction of CSP leads remain.

OBJECTIVE

The aim of the study was to report on the safety, feasibility, and clinical outcomes of the extraction of CSP leads.

METHODS

Patients undergoing the extraction of CSP leads from 10 international centers were enrolled in this retrospective study. Data regarding indications, lead location, lead type, extraction tools, procedural success, complications, and reimplantation in the conduction system were collected.

RESULTS

Overall, 341 patients (age 69 ± 15 years; female 117 (34%); cardiomyopathy 157 (46%); lead dwell time 22 ± 26 months) underwent the extraction of 224 His bundle pacing and 117 LBBAP leads (lumenless leads 321; stylet-driven leads 20). Complete procedural success was achieved in 338 (99%), while clinical success was 100% with retained distal fragments in 3 patients (1%). Among patients with a lead dwell time of >6 months (6-193 months; n = 226), manual extraction was successful in 198 (87%), mechanical tools in 22 (10%), and laser in 6 (3%). Femoral tools were necessary in 3 patients. Minor complications occurred in 7 patients (2.1%). Reimplantation in the conduction system was successful in 233 of 244 patients attempted (95%).

CONCLUSION

The overall success rates of the extraction of CSP leads were very high (although the LBBAP lead dwell time was <3 years), with a low need for extraction tools and minimal complication. Reimplantation in the conduction system is feasible and safe.

Для цитирования: Vijayaraman Pugazhendhi, Trivedi Rohan S, Koneru Jayanthi N, Sharma Parikshit S, De Pooter Jan, Schaller Robert D, Cano Óscar, Whinnett Zachary I, Migliore Federico, Ponnusamy Shunmuga Sundaram, Skeete Jamario R, Zanon Francesco, Heuverswyn Frederic V, Kolominsky Jeffrey, Pittorru Raimondo, Mumtaz Mishal, Ellenbogen Kenneth A, Herweg Bengt. Transvenous extraction of conduction system pacing leads: An international multicenter (TECSPAM) study.. Heart rhythm. 2024. DOI: 10.1016/j.hrthm.2024.04.054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.