MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8167.2009.01442.x

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2009

Human model simulating right ventricular outflow tract tachycardia by high-frequency stimulation in the left pulmonary artery: autonomics and idiopathic ventricular arrhythmias.

Hasdemir Can, Alp Alpay, Aydin Mehmet, Can Levent H

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Frequent monomorphic premature ventricular contractions (PVC) and/or ventricular tachycardia (VT) in patients with structurally normal heart usually arise from the right ventricular outflow tract (RVOT). An animal model simulating RVOT tachycardia by high-frequency stimulation (HFS) of the sympathetic input to the proximal pulmonary artery (PA) has been previously described. The aim of this study was to similarly induce RVOT tachycardia in humans.

METHODS

In 9 patients with no history of ventricular arrhythmias, a circumferential catheter was placed in the left, main, and proximal PA to contact the endovascular circumference of the PA. A 50-ms train of HFS (200 Hz/0.3 ms pulse duration), coupled to atrial pacing, was applied at each bipolar pair of the circumferential catheter. The coupling interval was adjusted so that the 50-ms train occurred during the ventricular refractory period.

RESULTS

In 6 out of 9 patients, HFS in the left PA during dobutamine infusion induced monomorphic PVCs and/or VT with left bundle branch block (LBBB) morphology and inferior axis at an average stimulation level of 12.5 +/- 2.7 V. HFS in the main PA and in the proximal PA did not induce any ventricular arrhythmias with the highest energy of 15 V in baseline state and during dobutamine infusion. HFS in the left PA was associated with hiccough in all patients.

CONCLUSION

Stimulation of the sympathetic input to the left PA during dobutamine infusion induces PVCs and/or VT exhibiting LBBB-morphology and inferior axis, closely simulating clinical RVOT tachycardia in humans.

Для цитирования: Hasdemir Can, Alp Alpay, Aydin Mehmet, Can Levent H. Human model simulating right ventricular outflow tract tachycardia by high-frequency stimulation in the left pulmonary artery: autonomics and idiopathic ventricular arrhythmias.. Journal of cardiovascular electrophysiology. 2009. DOI: 10.1111/j.1540-8167.2009.01442.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.