Transfusion · 2016
Discriminating complement-mediated acute transfusion reaction for type O+ red blood cells transfused into a B+ recipient with the complement hemolysis using human erythrocytes (CHUHE) assay.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cunnion Kenji M, Hair Pamela S, Krishna Neel K, Whitley Pamela H, Goldberg Corinne L, Fadeyi Emmanuel A, Maes Lanne Y
Аннотация
BACKGROUND: A patient with B+ sickle cell disease received 3 units of red blood cells (RBCs) from two O+ donors and developed fever and hypotension after the first unit, consistent with an acute transfusion reaction (ATR). Anti-B titers in plasma from each O+ donor were markedly elevated and nondiscriminatory. In order to evaluate the potential for the transfused units to produce complement-mediated hemolysis of B+ RBCs, hemolytic complement testing was performed.
STUDY DESIGN AND METHODS: Plasma from each donor was diluted in veronal buffer and incubated with B+ RBCs, and free hemoglobin was measured by spectrophotometer in the complement hemolysis using human erythrocytes (CHUHE) assay. Peptide inhibitor of complement C1 (PIC1) was used to confirm antibody-initiated complement pathway activation.
RESULTS: A 96-fold difference (p = 0.014) in hemolysis was measured between plasma samples from the two O+ donors using the CHUHE assay. The extremely high degree of hemolysis produced by the one plasma was inhibited by PIC1 in a dose-dependent manner.
CONCLUSION: These results indicate that hemolytic complement testing with the CHUHE assay can be used to assess the risk of antibody-initiated, complement-mediated hemolysis from a transfusion beyond what can be achieved with antibody titers alone.
STUDY DESIGN AND METHODS: Plasma from each donor was diluted in veronal buffer and incubated with B+ RBCs, and free hemoglobin was measured by spectrophotometer in the complement hemolysis using human erythrocytes (CHUHE) assay. Peptide inhibitor of complement C1 (PIC1) was used to confirm antibody-initiated complement pathway activation.
RESULTS: A 96-fold difference (p = 0.014) in hemolysis was measured between plasma samples from the two O+ donors using the CHUHE assay. The extremely high degree of hemolysis produced by the one plasma was inhibited by PIC1 in a dose-dependent manner.
CONCLUSION: These results indicate that hemolytic complement testing with the CHUHE assay can be used to assess the risk of antibody-initiated, complement-mediated hemolysis from a transfusion beyond what can be achieved with antibody titers alone.