MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-017-10264-7

Медицинская библиотека · Scientific reports · 2017

Application of color Doppler ultrasound combined with Doppler imaging artifacts in the diagnosis and estimate of congenital hypertrophic pyloric stenosis.

Ma Suihong, Liu Jianhua, Zhang Youxiang, Yang Yuwen, Jin Hai, Ma Xiaomei, Wei Hongqin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Congenital Hypertrophic Pyloric Stenosis (CHPS) is a disease condition that is caused as a result of pylorus wall hypertrophy and hyperplasia. In this study, we used color Doppler flow imaging (CDFI) and Doppler artifacts technique to observe the blood flow of hypertrophic pylorus tissue and the dynamic imaging of liquid passing through the pyloric canal in CHPS infants. 65 cases of CHPS infants and 50 infants without CHPS served as control group. We found that there were statistically significant differences between the blood flow grade of muscular layer and mucosal layer between CHPS and control infants, but no significant differences were observed in the same group. Doppler artifacts technique demonstrated the whole process of contrast agent flow through pyloric canal was directly observed in 35 of 65 subjects, and the internal diameter of the pyloric canal was 1.93 ± 0.33mm.Conclusion that CDFI combined with color Doppler artifacts technique was proved to be effective to observe the distribution feature and blood flow grade in each layer of pyloric canal in CHPS patients. This method provides the evidence for judging the degree of pyloric stenosis clinically, and furnishes the basis of therapy along with its clinical significance and good application value.

Для цитирования: Ma Suihong, Liu Jianhua, Zhang Youxiang, Yang Yuwen, Jin Hai, Ma Xiaomei, Wei Hongqin. Application of color Doppler ultrasound combined with Doppler imaging artifacts in the diagnosis and estimate of congenital hypertrophic pyloric stenosis.. Scientific reports. 2017. DOI: 10.1038/s41598-017-10264-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.