MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/scs.0000000000003871

Медицинская библиотека · The Journal of craniofacial surgery · 2017

Use of a Balloon Catheter With Intraoperative C-Arm Fluoroscan for Reduction of Zygomatic Arch Fractures.

Noh Woon Jae, Park Tae Jung, Kim Joo Yeon, Kwon Jae Hwan

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

The purpose of this study was to evaluate the usefulness of C-arm fluoroscan with a balloon catheter in patients undergoing closed reduction of zygomatic arch fractures.

SUBJECTS AND

METHODS

All patients who had zygomatic arch reduction surgery between 2006 and 2015 were identified and classified into 2 groups. Group A included those patients who underwent closed reduction of zygomatic arch fractures. Group B included those who underwent zygomatic arch reduction surgery with a C-arm fluoroscan and supporting balloon. A balloon catheter was used to stabilize the zygomatic bone after reduction. Results were scored from 1 (poor) to 3 (good) to assess surgical outcomes based on 3 criteria: alignment of the zygomatic arch on a postoperative computed tomography scan, facial asymmetry in photography, and the patient's subjective satisfaction.

RESULTS

The authors enrolled 32 patients with zygomatic arch fractures. 18 patients underwent closed reduction for zygomatic arch fractures (group A), while 14 patients underwent closed reduction with C-arm fluoroscan and balloon support (group B). The average score for group A was 2.00 for alignment, 2.56 for facial asymmetry, and 2.67 for subjective satisfaction compared with 2.64 for alignment, 2.86 for facial asymmetry, and 2.79 for subjective satisfaction in group B. There were statistically significant differences in the alignment and facial asymmetry scores between the 2 groups.

CONCLUSION

The authors suggest that C-arm fluoroscan with balloon support is a useful modality for reduction of zygomatic arch fractures that provides better surgical outcomes than conventional closed reduction surgery.

Для цитирования: Noh Woon Jae, Park Tae Jung, Kim Joo Yeon, Kwon Jae Hwan. Use of a Balloon Catheter With Intraoperative C-Arm Fluoroscan for Reduction of Zygomatic Arch Fractures.. The Journal of craniofacial surgery. 2017. DOI: 10.1097/scs.0000000000003871.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.