MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/10641959909016200

Медицинская библиотека · Hypertension in pregnancy · 1999

Antepartum middle mean cerebral blood flow velocity correlation with maternal hemodynamics.

Williams K P, Wilson S

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the correlation between simultaneous assessment of maternal middle cerebral blood flow velocity with the other maternal hemodynamic factors of cardiac output and mean arterial pressure.

STUDY

DESIGN

Eight normotensive patients were assessed. Maternal cerebral blood flow velocity was assessed using transcranial Doppler. Cardiac output was assessed noninvasively using the thoracic electrical bioimpedance technique over four cycles. Transcranial assessment of cerebral blood flow velocity was done over four cycles. Statistical analysis was then done using the Pearson correlation coefficient and linear regression analysis with stepwise regression. A p-value of < 0.05 was considered significant.

RESULTS

The value of the hemodynamic parameters were cardiac output 8.6 +/- 2.6 L/min, mean arterial pressure 82 +/- 9.7 mm Hg, and mean maternal cerebral blood flow velocity 59.6 +/- 11 cm/s. The pulsatility index was 0.85 +/- 0.15. The mean blood pressure could only explain 42% of the variation in systolic maternal cerebral blood flow velocity and 32% of the variation in mean maternal cerebral blood flow velocity. The mean middle cerebral blood flow velocity did not correlate with cardiac output.

CONCLUSIONS

Middle cerebral artery velocity correlates moderately with mean arterial pressure but not with cardiac output. The control of mean arterial pressure cannot be used as the only indicator of appropriate reduction in cerebral blood flow velocity.

Для цитирования: Williams K P, Wilson S. Antepartum middle mean cerebral blood flow velocity correlation with maternal hemodynamics.. Hypertension in pregnancy. 1999. DOI: 10.3109/10641959909016200.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.