MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jcpe.12416

Медицинская библиотека · Journal of clinical periodontology · 2015

Effect of application of a PVP-iodine solution before and during subgingival ultrasonic instrumentation on post-treatment bacteraemia: a randomized single-centre placebo-controlled clinical trial.

Sahrmann Philipp, Manz Andrea, Attin Thomas, Zbinden Reinhard, Schmidlin Patrick R

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

To assess the effect of concomitant subgingival rinsing with 10% PVP-iodine during subgingival instrumentation on the prevalence and magnitude of bacteraemia of oral origin.

MATERIALS AND

METHODS

Subgingival instrumentation was performed with water or PVP-iodine rinse in patients with periodontitis. Prior to instrumentation, subjects gargled for 1 min with the allocated liquid. Pockets were then rinsed for 1 min and subgingivally instrumented with liquid-cooled (water/PVP-iodine) ultrasonic scalers (1 min). Two minutes later, a blood sample from the arm vein was drawn using a lysis centrifugation blood culture system for quantitative microbiological analysis. Non-parametric statistical tests were performed to assess differences in the prevalence and extent of bacteraemia between groups.

RESULTS

Of the 19 samples in each group, oral-borne bacteraemia was detected in 10 of the control and 2 of the test samples. With an average of 3.0 [1; 5] colony forming units, significantly less bacteria and bacteraemia were found in the test group compared to the controls (12.2 [1; 46]) (p = 0.003). Anaerobic bacteria were not found in the test group.

CONCLUSIONS

Bacteraemia after subgingival instrumentation with concomitant PVP-iodine rinsing is reduced but not eliminated. Therefore, it might be recommended for patients at a high risk of endocarditis or infection of endoprostheses. However, preventive antibiotic treatment should not be omitted.

Для цитирования: Sahrmann Philipp, Manz Andrea, Attin Thomas, Zbinden Reinhard, Schmidlin Patrick R. Effect of application of a PVP-iodine solution before and during subgingival ultrasonic instrumentation on post-treatment bacteraemia: a randomized single-centre placebo-controlled clinical trial.. Journal of clinical periodontology. 2015. DOI: 10.1111/jcpe.12416.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.