m+Medelevator.RU
← Поиск публикаций
Obstetrics and gynecology · 2026

Multicenter Evaluation of an Artificial Intelligence System for Automatic Recognition of Fetal Ultrasound Findings Suggestive of Congenital Malformations.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Morisset Clémentine, Logé-Munerel Frédéric, Debavelaere Vianney, Besson Rémi, Turan Sifa, Fries Nicolas, Stirnemann Julien, Oyelese Yinka, Ville Yves

Аннотация

OBJECTIVE: To evaluate the diagnostic performance of an artificial intelligence (AI) system for detecting eight abnormal fetal ultrasound findings across cephalic, thoracic, and abdominal regions in routine, unfiltered, multicenter images.

METHODS: We performed a multicenter, retrospective evaluation of an AI software that detects eight abnormal ultrasound findings on still images. Ground truth was established by a multidisciplinary panel (board-certified reviewers with 5 or more years of experience) using a three-step process (view identification, structure visibility, sign presence or absence) with majority consensus. The software evaluated eight findings on six standard views: absence of the cavum septum pellucidum, absence of the corpus callosum, malposition of the great vessels, absence or unusual size of one of the three vessels, disequilibrium or absence of at least one of the two ventricles, thoracic situs inversus, abdominal situs inversus, and nonvisibility of a single stomach bubble or abnormally big stomach. For thoracic and abdominal situs, an evaluability step preceded classification. Primary end points were sensitivity and specificity per finding on evaluable images, with subgroup analyses by geography, device manufacturer, trimester, body mass index (BMI), demographics, anatomy, indication, and finding status. Cluster bootstrap accounted for within-patient clustering; multiplicity was controlled with Bonferroni or Hochberg correction.

RESULTS: We analyzed 6,452 images from 1,115 examinations (11-41 weeks of gestation) from approximately 1,000 pregnancies in 942 patients across 75 international sites over five countries; 6,094 images contributed to performance estimates. Mean sensitivity for AI detection was 93.2% (95% CI, 91.6-94.6%) and mean specificity was 90.8% (95% CI, 89.5-92.0%) across the eight findings. Sensitivity was superior to 87% and specificity was superior to 81% for all findings. Abdominal situs inversus had the highest performance (sensitivity 99.3%, 95% CI, 97.6-100%; specificity 99.3%, 95% CI, 98.4-100%). Among thoracic findings, sensitivity was lowest for malposition of the great vessels (87.7%), and specificity was lowest for absence or unusual size of at least one of the three vessels (81.5%). Subgroup performance was generally consistent across manufacturers, regions, BMI categories, and trimesters.

CONCLUSION: In a heterogeneous, multicenter dataset, the software reliably identified predefined ultrasound findings suggestive of congenital malformations. These results support its potential as a real-time assistant to standardize interpretation and to flag suspicious findings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты