Vital sign parameters are not associated with electrical capture during transcutaneous pacing.

Kimbrell Joshua M, Kreinbrook Judah A, Smida Tanner, Gan Gabriel H, Odom Wesley, Shukis Michael, Bardes James

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Failure to achieve electrical capture during transcutaneous pacing (TCP) is common and underrecognized. We aimed to identify whether pulse oximetry plethysmograph waveform synchrony, end-tidal capnometry increases, and systolic blood pressure increases were associated with sustained electrical capture during prehospital TCP.

METHODS

This secondary analysis of a multi-center retrospective observational study enrolled patients from four emergency medical service agencies. Sustained electrical capture was defined as a wide QRS and T wave for ≥90% of ongoing TCP time. Pulse oximetry plethysmograph wave synchronization with the TCP rate and vital sign values were obtained from cardiac monitor/defibrillator files. A diagnostic framework was used to evaluate plethysmograph synchronization. We used linear regression modeling to detect whether increases in end-tidal carbon dioxide (ETCO2) and blood pressure measurements were associated with sustained electrical capture.

RESULTS

Of 253 patients, 29 (11.5%) had sustained electrical capture. An increase in SBP had a sensitivity of 75.0% (42.8, 94.5) and a specificity of 40.0% (29.8, 50.9) for the outcome of sustained electrical capture. An increase in ETCO2 had a sensitivity of 41.7% (15.2, 72.3) and a specificity of 64.4% (53.7, 74.3). Linear regression modeling did not suggest that sustained electrical capture was associated with post-TCP SBP (-2.5 mmHg (-27.3, +22.4)) or post-TCP ETCO2 (2.6 mmHg (-2.9, +8.1)). Plethysmograph synchronization had a sensitivity of 58.8% (32.9, 81.6) and a specificity of 81.1% (73.2, 87.5).

CONCLUSIONS

These findings suggest that plethysmograph waveforms, capnometry, and blood pressure monitoring alone are not reliable indicators of electrical capture during TCP performed by paramedics.

Для цитирования: Kimbrell Joshua M, Kreinbrook Judah A, Smida Tanner, Gan Gabriel H, Odom Wesley, Shukis Michael, Bardes James. Vital sign parameters are not associated with electrical capture during transcutaneous pacing.. The American journal of emergency medicine. 2026. DOI: 10.1016/j.ajem.2026.07.050.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.