AIMS: Translabial 3D/4D pelvic floor ultrasound (PFUS) is increasingly used in the evaluation of pelvic floor disorders. Commonly, this involves the analysis of stored volume data sets by postprocessing. In this study, we aimed to assess the time requirement to reaching acceptable repeatability for commonly employed outcome measures in PFUS.

METHODS

Between 2010 and 2013, 20 individuals from 11 countries underwent training in postprocessing of PFUS volume data sets. They undertook test-retest series (n ≥ 20) between day 2 and day 15 of training. Outcome measures tested included levator hiatal area on Valsalva, descent of the bladder neck, bladder, uterus and rectal ampulla, and rectocele depth. After an initial training session of 10-20 cases, test-retest series were undertaken between the trainee and measurements obtained by the author or senior trainees.

RESULTS

Trainees were obstetricians/gynaecologists in training (n = 4), obstetricians/gynaecologists or subspecialty trainees (n = 13), medical students (n = 1) and physiotherapists (n = 2). A total of 58 repeatability series were analysed, obtained between days 2 and 15 of training. When second or third retest series were necessary, there always was improvement in repeatability except for one series in one individual. Satisfactory repeatability (ICC > 0.7) was achieved by all trainees for all parameters required by them. Training lasted from 3 to 15 days, with means between 4 and 5.8 days.

CONCLUSIONS

Postprocessing analysis of commonly used PFUS parameters can be taught to an acceptable standard within 1 week. Most commonly used ultrasound parameters obtained by postprocessing for prolapse assessment can be taught to an acceptable standard of repeatability within one week.

Для цитирования: Dietz Hans P, Rojas Rodrigo Guzman, Shek Ka Lai. Postprocessing of pelvic floor ultrasound data: how repeatable is it?. The Australian & New Zealand journal of obstetrics & gynaecology. 2014. DOI: 10.1111/ajo.12250.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.