MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/09691413231173315

Медицинская библиотека · Journal of medical screening · 2023

Cell-free DNA-based prenatal screening via rolling circle amplification: Identifying and resolving analytic issues.

Palomaki Glenn E, Lambert-Messerlian Geralyn M, Fullerton Donna, Hegde Madhuri, Conotte Stéphanie, Saidel Matthew L, Jani Jacques C

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

A rolling circle amplification (RCA) based commercial methodology using cell-free (cf)DNA to screen for common trisomies became available in 2018. Relevant publications documented high detection but with a higher than expected 1% false positive rate. Preliminary evidence suggested assay variability was an issue. A multi-center collaboration was created to explore this further and examine whether subsequent manufacturer changes were effective.

METHODS

Three academic (four devices) and two commercial (two devices) laboratories provided run date, chromosome 21, 18, and 13 run-specific standard deviations, number of samples run, and reagent lot identifications. Temporal trends and between-site/device consistency were explored. Proportions of run standard deviations exceeding pre-specified caps of 0.4%, 0.4% and 0.6% were computed.

RESULTS

Overall, 661 RCA runs between April 2019 and July 30, 2022 tested 39,756 samples. In the first 24, subsequent 9, and final 7 months, proportions of capped chromosome 21 runs dropped from 39% to 22% to 6.0%; for chromosome 18, rates were 76%, 36%, and 4.0%. Few chromosome 13 runs were capped using the original 0.60%, but capping at 0.50%, rates were 28%, 16%, and 7.6%. Final rates occurred after reformulated reagents and imaging software modifications were fully implemented across all devices. Revised detection and false positive rates are estimated at 98.4% and 0.3%, respectively. After repeat testing, failure rates may be as low as 0.3%.

CONCLUSION

Current RCA-based screening performance estimates are equivalent to those reported for other methods, but with a lower test failure rate after repeat testing.

Для цитирования: Palomaki Glenn E, Lambert-Messerlian Geralyn M, Fullerton Donna, Hegde Madhuri, Conotte Stéphanie, Saidel Matthew L, Jani Jacques C. Cell-free DNA-based prenatal screening via rolling circle amplification: Identifying and resolving analytic issues.. Journal of medical screening. 2023. DOI: 10.1177/09691413231173315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.