Straight-to-test faecal tagging CT colonography for exclusion of colon cancer in symptomatic patients under the English 2-week-wait cancer investigation pathway: a service review.
Аннотация
AIM: To present the initial 12 months of data of a straight-to-test (STT) computed tomography colonography (CTC) protocol as the first-line investigation for change in bowel habit (CIBH) and iron deficiency anaemia (IDA) in patients over 60 referred directly from primary care.
MATERIALS AND
METHODS
In 12 months, 1,792 STT CTC for IDA and CIBH were performed. No colonoscopies were performed as the primary investigation in this cohort. Data from this cohort were gathered prospectively.
RESULTS
The colorectal cancer (CRC) detection rate was 4.9% and polyp detection rate was 13.5%. The CRC rate increased related to age (p=0.001), the CRC detection rate was 2.6% in patients aged 60-69 years, compared to 4.9%, 7.4%, and 11.4% in the 70-79, 80-89, and >90 years age groups. The CRC rate was higher in patients with IDA compared to CIBH (6.8% versus 3.9%, p=0.017). There were significantly more left-sided cancers (p=0.0165). Non-colonic cancers were found in 4.3% of patients and 6.8% had incidental findings that required further investigation and 11.9% had a new, potentially significant, incidental finding.
CONCLUSION
These results are comparable to colonoscopy in terms of diagnostic accuracy and similar to those of CTC in published multicentre trials. This exciting model of care within radiology enables earlier testing, reduces waiting times, with fewer outpatient appointments, and results in good clinician and patient satisfaction.