MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.medcli.2008.10.061

Медицинская библиотека · Medicina clinica · 2009

[Diagnostic reliability of anaerobic blood cultures in bacteremias from a critical care unit].

Ruiz-Giardín José Manuel, Alonso Mercedes, Jaquetti Jerónimo, Sánchez Susana, Saldaña Teresa, Zapatero Antonio

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

This is a descriptive study of bacteraemias diagnosed in ICU with an analysis of the diagnostic reliability of anaerobic blood cultures.

PATIENTS AND METHOD: Analysis of all positive blood cultures in an Intensive Care Unit from May 2005 to October 2007.

RESULTS

The overall incidence of true bacteraemia was 6,1% of admissions. Out of 100 patients, there were 73 bacteraemias and 52 contaminated cultures. Samples with contaminated cultures were drawn 6,27 days earlier (CI 95% 0,61-11,94 Sig:0,03) than true bacteraemia. Most frequent micro organisms were cocci gram positive: 43 cases (58,9%) (coagulase-negative staphylococci was the most frequent: 30 or 41% of all bacteraemia)) Sig=0,001 in relation with gram negatives. Anaerobic micro organisms were not detected. Candidemias were found in 10 cases (13,7%). The most frequent causes of bacteraemia in this study were catheter-related infections with 36 cases (49,3% Sig<0,005), followed by digestive origin infections in 14 (19,2%). Of all bacteremic episodes (73 bacteraemia), 66 (90,4%) were isolated in aerobic blood cultures, and 58 (79,5%) were in anaerobic ones, with a difference of 10,9% Sig:0,06. When only intrahospitalary bacteraemias were analyzed, there was a difference of 13,56% of more yields in aerobic blood cultures; Sig:0,04 (IC 95% 0,8%-26%)). Candidemias were isolated only in aerobic blood cultures; Sig:0,001. When analyzing coagulase negative staphylococci, there were 30 bacteraemias and 41 contaminated samples. 62 (87,3%) were isolated in aerobic blood cultures and 50 (70,4%) in anaerobic ones, with a difference of 16,9% Sig=0,01,CI 95%(3%-30%).

CONCLUSIONS

In the Critical Care Unit, it would be possible to change the anaerobic blood cultures by aerobic ones to diagnose bacteraemias of intrahospitalary acquisition. This fact should be analyzed with others studies.

Для цитирования: Ruiz-Giardín José Manuel, Alonso Mercedes, Jaquetti Jerónimo, Sánchez Susana, Saldaña Teresa, Zapatero Antonio. [Diagnostic reliability of anaerobic blood cultures in bacteremias from a critical care unit].. Medicina clinica. 2009. DOI: 10.1016/j.medcli.2008.10.061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…