MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/prs.0000000000011178

Медицинская библиотека · Plastic and reconstructive surgery · 2023

Cadaveric Feasibility Study on Modified Contralateral C7 Nerve Transfer for Targeted Recovery in Hemiplegic Arms.

Zhu Shuai, Ye Xuan, Feng Jun-Tao, Li Tie, Yin Hua-Wei, Qiu Yan-Qun, Xu Wen-Dong, Shen Yun-Dong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Contralateral cervical seventh (cC7) nerve to C7 transfer has been proven effective for treating spastic upper limb. However, for those whose major impairment is not in the C7 area, cC7 nerve transfer to other nerves may achieve a better outcome. The aim of this study was to explore the optimal surgical approach for transferring cC7 to 1 or 2 nerves in a cadaveric study, and to evaluate possible applications for patients with hemiplegia.

METHODS

Modified cC7 transfer to 1 (5 procedures) or 2 nonadjacent (3 procedures) nerve roots was proposed, and success rates of direct coaptation through 2 surgical approaches-the superficial surface of longus colli (sLC) and the deep surface of longus colli (dLC) approach-were compared. The length, diameter, and distance of relevant nerves were also measured in 25 cadavers.

RESULTS

Compared with the sLC approach, the distance of the dLC approach was 1.1 ± 0.3 cm shorter. The success rates for the sLC and dLC approaches were as follows: cC7 to C5 surgery, 94%, and reached 98%; cC7 to C6 surgery, 54% and 96%; cC7 to C7 surgery, 42% and 94%; cC7 to C8 surgery, 34% and 94%; cC7 to T1 surgery, 24% and 62%; cC7 to C5C7 surgery, 74% and 98%; cC7 to C6C8 surgery, 54% and 98%; and cC7 to C7T1 surgery, 42% and 88%.

CONCLUSIONS

The dLC approach greatly improved the direct coaptation rate for cC7 nerve transfer. The modified cC7 nerve transfer procedures are technically feasible for further application in clinic.

Для цитирования: Zhu Shuai, Ye Xuan, Feng Jun-Tao, Li Tie, Yin Hua-Wei, Qiu Yan-Qun, Xu Wen-Dong, Shen Yun-Dong. Cadaveric Feasibility Study on Modified Contralateral C7 Nerve Transfer for Targeted Recovery in Hemiplegic Arms.. Plastic and reconstructive surgery. 2023. DOI: 10.1097/prs.0000000000011178.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.