DOI 10.3748/wjg.v31.i11.103178
Role of transient elastography in the diagnosis and prognosis of Fontan-associated liver disease.
Аннотация
BACKGROUND
Fontan-associated liver disease (FALD) often occurs in patients with single-ventricle physiology following Fontan surgery, and ranges from liver congestion to cirrhosis. The assessment of the severity of FALD using noninvasive methods is challenging. However, transient elastography (TE) may be useful for the noninvasive evaluation of FALD and prediction of clinical outcomes.
AIM: To evaluate the role of TE in the diagnosis of FALD and its association with clinically relevant events.
METHODS
This retrospective single-center study (Hospital Universitario La Paz, Madrid), including 91 post-Fontan patients aged > 18 years old. Laboratory and ultrasound findings, and liver stiffness measurements (LSM) by TE (FibroScan®) were assessed. FALD was defined using ultrasound criteria (hepatomegaly, liver surface nodularity, parenchymal heterogeneity, hyperechoic lesions, splenomegaly, collaterals) and advanced FALD was defined according to the European Association for the Study of the Liver-European Reference Network statement (esophageal varices, portosystemic shunts, ascites, splenomegaly). Clinically relevant events included heart or heart-liver transplantation indication, hepatocellular carcinoma, and all-cause mortality.
RESULTS
Patient characteristics were: 60.4% male; Mean age, 33.3 ± 8.2 years; Mean elapsed time since surgery, 24.3 ± 7.7 years; 89% with FALD; 73% with advanced FALD. LSM by TE was associated with FALD [odds ratio (OR) = 1.34; 95% confidence interval (95%CI): 1.10-1.64; P = 0.003] and advanced FALD (OR = 1.10; 95%CI: 1.01-1.19; P = 0.023). Areas under the curve (AUC) were 0.905 and 0.764 for FALD and advanced FALD, respectively. FALD cut-off values comprised: Optimal, 20 kPa (sensitivity: 92.3%; specificity: 80.0%); Rule-out, 15 kPa (sensitivity: 96.9%); Rule-in, 25 kPa (specificity: 100%). A FALD algorithm was proposed based on LSM by TE and elapsed time since surgery (AUC: 0.877; sensitivity, 95.4%; specificity, 80.0%; positive predictive value, 96.9%; negative predictive value, 72.7%). LSM by TE was associated with clinically relevant events (OR = 1.07; 95%CI: 1.01-1.13; P = 0.021) and all-cause mortality (OR = 1.23; 95%CI: 1.02-1.47; P = 0.026).
CONCLUSION
In adult patients post-Fontan surgery, TE is a useful noninvasive method for FALD diagnosis. The association between LSM by TE and clinically relevant events suggests a role in prognosis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.