MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjci/jeag089

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2026

Funnel-type patent foramen ovale morphology on 3D echocardiography: a novel high-risk anatomic feature.

Totaro Antonio, Sacra Cosimo, Testa Gianluca, Galluccio Chiara, Iannace Marianna, Magri Gianludovico, Tota Antonio, Pierro Antonio, Onorato Eustaquio, Dell'Aquila Michele, Condello Ignazio, Katsavrias Konstantinos, Moccia Francesco, Calafiore Antonio Maria

СтатьяПеревод в очереди

Аннотация

AIMS: Cryptogenic strokes are associated with patent foramen ovale (PFO), but accurate risk assessment remains difficult. To better identify clinical and anatomical high-risk profiles, we describe a morphological classification of PFO using 3D transoesophageal echocardiography (TEE).

METHODS AND

RESULTS

3D-TEE was performed in 95 consecutive patients with a right-to-left shunt. A classification was made based on the internal geometry: 'cone type' (wider left atrial end) and 'funnel type' (wider right atrial [RA] end). Morphology was related to the clinical history of ischaemic stroke or transient ischaemic attack (events). Thirty-seven (38.9%) had prior events. This group had a larger cross-sectional area of the RA opening (48.5 [18.4-67.0] vs. 11.75 [8.6-17.9] mm2, P = 0.002). Funnel morphology was more common in the event group (81.1% vs. 50%, P = 0.001) and was associated with more than twice the rate of events than cone morphology (50.8% vs. 19.4%, P = 0.002). On multivariable analysis, dyslipidaemia (odds ratio [OR] 21.06), smoking (OR 6.25), funnel morphology (OR 6.47), and a larger RA opening area (OR 1.026 per mm2) were independent predictors of events. Receiver operating characteristic analysis identified an RA opening area >15.85 mm2 as the optimal cut-off to predict events (area under the curve 0.719).

CONCLUSION

Prior events are highly correlated with funnel-type PFO, particularly when RA opening area exceeds 15.85 mm2. This geometry may act as an embolic 'catchment' and favour in situ thrombosis due to disturbed flow from the wide RA inlet to the narrow tunnel exit. Integration of 3D-TEE morphology with systemic risk factors such as smoking and dyslipidaemia may refine patient stratification and guide management.

Для цитирования: Totaro Antonio, Sacra Cosimo, Testa Gianluca, Galluccio Chiara, Iannace Marianna, Magri Gianludovico, Tota Antonio, Pierro Antonio, Onorato Eustaquio, Dell'Aquila Michele, Condello Ignazio, Katsavrias Konstantinos, Moccia Francesco, Calafiore Antonio Maria. Funnel-type patent foramen ovale morphology on 3D echocardiography: a novel high-risk anatomic feature.. European heart journal. Cardiovascular Imaging. 2026. DOI: 10.1093/ehjci/jeag089.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.