DOI 10.1016/j.bjps.2013.05.018
Human acellular dermal matrix (AlloDerm®) dimensional changes and stretching in tissue expander/implant breast reconstruction.
Аннотация
BACKGROUND
Human acellular dermal matrix (HADM) is widely used for post-mastectomy tissue expander/implant breast reconstruction. Since HADM has been shown to stretch following placement in other surgical settings, we hypothesised that stretching would occur in breast reconstruction as well. The goal of the study was to quantify the in situ stretch properties of HADM over time in patients undergoing this procedure.
METHODS
This was an open-label, prospective case series in adult women who underwent post-mastectomy tissue expander/implant breast reconstruction using HADM. HADM construct size was determined at postoperative day 1 and month 3 via ultrasound tracking of metallic 3-mm vessel clips embedded in the graft. Dimensional changes were further examined in four equally sized segments (medial, lateral and two central) of the matrix. Patient satisfaction was evaluated at month 3 (a modified version of the Breast Q™ patient questionnaire) and compared with satisfaction reported by a non-HADM reconstruction cohort.
RESULTS
A total of 31 patients underwent breast reconstruction with HADM. Mean (standard deviation) perimeter increased from 38 (6) cm on postoperative day 1-42 (7) cm at month 3 (+11%; P=0.002). Surface area increased from 73 (22) to 88 (28) cm2 (+21%; range, 4-35%; P=0.002). The greatest expansion occurred in the HADM medial and lateral segments (range, 18-30% across the four segments). Patient satisfaction was comparable with that of non-HADM patients. Complications in the HADM group included late seroma, red breast syndrome and urinary tract infection. Complications in the non-HADM cohort included cellulitis, expander explantation, delayed wound healing and skin necrosis.
CONCLUSIONS
During short-term follow-up, HADM exhibited a modest degree of stretching during tissue expander/implant breast reconstruction and was associated with few complications and a high level of patient satisfaction.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.