MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/jum.2008.27.5.737

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2008

Ultrasonographic measurements of the ulnar nerve at the elbow: role of confounders.

Thoirs Kerry, Williams Marie A, Phillips Maureen

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to identify factors confounding high-resolution ultrasonographic measurements of the ulnar nerve to test their influence when discriminating between limbs affected and unaffected by ulnar nerve entrapment (UNE) at the elbow.

METHODS

High-resolution ultrasonographic measurements of ulnar nerve dimensions at the elbow were compared between 2 groups of subjects: symptomatic and asymptomatic for UNE. Rank analysis of covariance regression tests were performed to determine whether significant differences existed between the 2 groups. The changing coefficient method (using rank analysis of covariance tests) was used to test for potential confounding effects of age, weight, height, body mass index, sex, limb sidedness, limb handedness, and nerve mobility. These tests were repeated for each measurement while controlling for the identified confounders. Exact 2-tailed Wilcoxon signed rank tests were performed to test for significant differences between measurements of the diameter of the ulnar nerve with the elbow in full extension and full flexion.

RESULTS

Age, weight, body mass index, sex, and elbow position were shown to have confounding influences on high-resolution ultrasonographic measurements of the ulnar nerve. No confounding effect was apparent for limb sidedness or dominance. Cross-sectional area and long-axis diameter measurements demonstrated significant differences between nerves with and without UNE after controlling for confounders.

CONCLUSIONS

Two cross-sectional measurements (area and maximum cross-sectional diameter) of the ulnar nerve, made at the level of the medial epicondyle, were found to be robust discriminators between nerves with and without UNE. In the absence of normative reference values of the ulnar nerve, the contralateral limb may be used as the comparative control.

Для цитирования: Thoirs Kerry, Williams Marie A, Phillips Maureen. Ultrasonographic measurements of the ulnar nerve at the elbow: role of confounders.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2008. DOI: 10.7863/jum.2008.27.5.737.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.