MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.112009

Медицинская библиотека · Cureus · 2026

Radiographic Documentation of Implant-Supported Rehabilitation Following Endodontic Failure of a Mandibular First Molar: A Case Report.

Mejia Ocampo Evelin M, Mora Vanessa, Romero Marcelo, Perez Quevedo Maryory, De la Roche Isis C

Клинический случайСтатьяПеревод в очереди

Аннотация

Endodontic failure is a common cause of tooth loss and frequently requires extraction when persistent infection and associated pathology compromise long-term prognosis. Dental implants provide a predictable treatment option for replacing missing teeth while restoring function and esthetics. This case report describes the radiographic documentation of implant-supported rehabilitation following endodontic failure of a mandibular first molar in a 44-year-old female patient. Initial radiographic evaluation revealed a previously endodontically treated mandibular right first molar (tooth #30) associated with persistent periapical pathology and an unfavorable prognosis. The tooth was extracted, and ridge preservation was performed using a bone graft material and a barrier membrane. After a three-month healing period, implant placement was completed with radiographic verification of implant position and proximity to adjacent structures using a guide pin. Following osseointegration, restorative procedures were initiated after implant uncovering through a digital workflow utilizing an intraoral scanner, scan body, and laboratory-fabricated screw-retained zirconia crown. Sequential radiographs documented the diagnostic, surgical, and restorative phases of treatment, including extraction site preservation, implant placement, healing, and definitive restoration. The final outcome demonstrated successful implant-supported rehabilitation with satisfactory radiographic positioning and restoration of function. This case highlights the value of radiographic assessment throughout implant therapy and illustrates a predictable treatment approach for replacing a mandibular first molar affected by endodontic failure.

Для цитирования: Mejia Ocampo Evelin M, Mora Vanessa, Romero Marcelo, Perez Quevedo Maryory, De la Roche Isis C. Radiographic Documentation of Implant-Supported Rehabilitation Following Endodontic Failure of a Mandibular First Molar: A Case Report.. Cureus. 2026. DOI: 10.7759/cureus.112009.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.