MedElevator Войти в исследования
← Поиск публикаций

DOI 10.13201/j.issn.2096-7993.2024.09.020

Медицинская библиотека · Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2024

[Treatment of congenital bilateral choanal atresia by low temperature plasma ablation and fully degradable sinus drug stent: a case report].

Ding Zan, Yang Liu, Liu Yuxin, Cui Xin, Li Da, Dong Jinye

Клинический случайСтатьяАннотация на английскомПеревод в очереди

Аннотация

To investigate the application of low temperature plasma ablation combined with fullly degradable sinus stent system in the treatment of congenital choanal atresia mainly menbranous atresia. A child with membranous bilateral choanal atresia admitted in April 2023 was analyzed. This case underwent endoscopic ablative posterior nostriplasty and placed a fully degradable drug stent in bilateral operative cavities. The case's nasal ventilation was effectively improved after operation and the profile of postnaris was well formed. No restenosis oratresia was found under electronic nasopharyngoscope and the drug stent was completely degraded after 8 months follow-up. Low temperature plasma ablation has the advantages of reducing surgical trauma, protecting normal tissue and avoiding complications in the treatment of congenital choanal atresia. At the same time, combined with the application of the fully degradable sinus drug stent, it can achieve remarkable efficacy by alleviating mucosal edema, reducing granulation tissue hyperplasia, accelerating wound mucosification, and effectively reducing the incidence of nasal adhesion, restenosis or even atresia.

Для цитирования: Ding Zan, Yang Liu, Liu Yuxin, Cui Xin, Li Da, Dong Jinye. [Treatment of congenital bilateral choanal atresia by low temperature plasma ablation and fully degradable sinus drug stent: a case report].. Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery. 2024. DOI: 10.13201/j.issn.2096-7993.2024.09.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.