MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0218492309102494

Медицинская библиотека · Asian cardiovascular & thoracic annals · 2009

Folic acid-based intervention in non-ST elevation acute coronary syndromes.

Imasa Marcelo Severino B, Gomez Neil T, Nevado Jose B

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

A mixture model of crown-rump length (CRL)-dependent and CRL-independent nuchal translucency (NT) measurements has been proposed for antenatal screening for Down's syndrome. We here compare the efficacy of the mixture model method with the standard method, which uses NT multiple of the median (MoM) values in a single distribution. Settings A routine antenatal screening programme for Down's syndrome comprising 104 affected and 22,284 unaffected pregnancies.

METHODS

The ability of NT to distinguish between affected and unaffected pregnancies was compared using the mixture model method and the standard MoM method by using published distribution parameters for the mixture model of NT and parameters derived from these for the standard MoM method. The accuracy of the two methods was compared for NT and maternal age by comparing the median estimated risk with the prevalence of Down's syndrome in different categories of estimated risk.

RESULTS

Using NT alone observed estimates of discrimination using the two methods are similar; at a 70% detection rate the false-positive rates were 12% using the mixture model method and 10% using the MoM method. Risk estimation was marginally (but not statistically significantly) more accurate using the standard MoM method.

CONCLUSIONS

The mixture model method offers no advantage over the standard MoM method in antenatal screening for Down's syndrome, is more complicated and less generalizable to other data-sets. The standard MoM method remains the method of choice.

Для цитирования: Imasa Marcelo Severino B, Gomez Neil T, Nevado Jose B. Folic acid-based intervention in non-ST elevation acute coronary syndromes.. Asian cardiovascular & thoracic annals. 2009. DOI: 10.1177/0218492309102494.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.