MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/andr.12771

Медицинская библиотека · Andrology · 2020

Validation of ultrasound biomicroscopy for the assessment of xenogeneic testis tissue grafts and cell implants in recipient mice.

Fayaz Mohammad Amin, Awang-Junaidi Awang Hazmi, Singh Jaswant, Honaramooz Ali

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Subcutaneous grafting/implantation of neonatal testis tissue/cells from diverse donor species into recipient mice can be used as an in vivo model to study testis development, spermatogenesis, and steroidogenesis. Ultrasound biomicroscopy (UBM) allows obtaining high definition cross-sectional images of tissues at microscopic resolutions.

OBJECTIVES

The present study was designed to (a) validate the use of UBM for non-invasive monitoring of grafts/implants overtime and to (b) correlate UBM findings with the morphological attributes of recovered grafts/implants.

MATERIALS AND

METHODS

Testis tissue fragments (~14 mm3 , each) and cell aggregates (100 × 106 cells, each) obtained from 1-week-old donor piglets (n = 30) were grafted/implanted under the back skin of immunodeficient mice (n = 6) in eight analogous sites per mouse. Three-dimensional transcutaneous Doppler UBM was performed, and a randomly selected graft and its corresponding implant were recovered at 2, 4, 6, and 8 weeks.

RESULTS

Graft/implant weight (P = .04) and physical height (P = .03) increased overtime. The dynamics of physical length and volume increases over time differed between tissue grafts and cell implants (P = .02 and 0.01 for sample type*time interactions, respectively). UBM-estimated volume was correlated with the post-recovery weight and volume of the grafts/implants (r = 0.98 and r = 0.99, respectively; P < .001). Pre- and post-recovery length and height of the grafts/implants were positively and strongly correlated (r = 0.50, P = .01; r = 0.70, P = .001) and so were the areas covered by cordal, non-cordal, or fluid-filled cavities between UBM and histology (r = 0.87, P < .001).

DISCUSSION AND

CONCLUSION

UBM findings correlated with physical attributes of the grafts/implants, validating its use as a non-invasive high-fidelity tool to quantify the developmental changes in ectopic testis tissue grafts and cell implants, potentially leading to a reduction in the number of recipient mice needed for similar experiments.

Для цитирования: Fayaz Mohammad Amin, Awang-Junaidi Awang Hazmi, Singh Jaswant, Honaramooz Ali. Validation of ultrasound biomicroscopy for the assessment of xenogeneic testis tissue grafts and cell implants in recipient mice.. Andrology. 2020. DOI: 10.1111/andr.12771.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.